Countertop Icemaker IMD Series Installation Manual

INSTALLATION INSTRUCTIONS

REMOVE ICEMAKER FROM CARTON

1.Keep unit in the upright position, remove carton and pallet from unit and inspect unit for damage. Upon inspection of unit, if any damage is found, file a claim with carrier immediately.

2.Locate Startup Card either on outside of container or on plastic liner. Fill in proper information and send one copy to factory, and other copy to Distributor. Postage is prepaid.

CABINET REMOVAL

1.Locate and remove the (2) screws from under the front cover. Lift cover forward and up to remove.

2.Lift up front edge of top cover. Slide back about 1/2 inch and remove.

3.Remove (6) screws from the front of the machine.

4.Remove side panels by sliding the front edge out and then back slightly to disengage.

5.Remove the front splash panel by lifting slightly to disengage the front, then tilt forward and remove.

6.Remove bin top and remove shipping insert.

PREPARATION OF INSTALLATION SITE

1.The refrigeration system on air cooled units requires airflow, so a well ventilated area should be chosen. A minimum of (6) inches must be maintained, free of any obstruction, for air intake. A min- imum of (4) inches clearance is required of air exhaust.

2.With template provided make the necessary provisions in the counter for water, drain and the elec- trical hook-up. Provisions are available for rear and bottom connections of water and electrical. Use hole plugs provided to plug unused holes.

WATER INLET HOOK-UP

1.Water Inlet - Fitting is a 1/4” SAE male flare located at the rear of the unit. Connect water supply with a 1/4” or larger copper or flexible tubing.

2.Water Pressure - Unless otherwise specified, the unit is designed to operate on water pressures between 10 P.S.I. and 90 P.S.I. (NOTE: for pressures above 90 P.S.I. a regulator must be installed).

3.Water Cooled Condensers

A.Inlet to modulating valve uses 3/8” FPT. Use separate 3/8” or larger water line.

B.Outlet is 3/8” FPT.

4.Filter Conditioner are recommended on supply lines to icemakers. Never run the water supply to water cooled Condenser through Filter/Conditioner, it uses up the cartridge unnecessarily and a saturated cartridge can starve the icemaker causing premature component damage. Separate water supplies are recommended.

NOTE: Unit must be installed per local plumbing code.

ELECTRICAL SUPPLY

1.Power Access - Is provided by way of a 7/8” dia. hole in both the base and the rear panel. Route incoming power in conduit, to icemaker electrical control box. Make connections to wires provided in control box and ground lug/screw. Plug unused hole.

2.Fused Line - Should be a dedicated circuit checked and sized according to electrical rating shown on unit nameplate.

NOTE: Unit must be installed per local electrical code.

Publication Number: 638085277INS

- 4 -

© 2004-2009, IMI Cornelius Inc.

Page 8
Image 8
Cornelius IMD Series installation manual Installation Instructions

IMD Series specifications

The Cornelius IMD (Intelligent Dispensing) Series represents a cutting-edge advancement in beverage dispensing technology, making it ideal for a wide array of establishments, including restaurants, cafeterias, and bars. This innovative series is designed to provide ultimate flexibility in drink variety while enhancing efficiency and reducing operational costs.

One of the standout features of the Cornelius IMD Series is its advanced touchscreen interface. This user-friendly screen allows operators to navigate through beverage selections easily. Customizable menus enable businesses to showcase their unique drink offerings prominently. The interface can also be programmed to highlight promotions or new items, ensuring customers are always informed about their options.

In addition to the intuitive interface, the Cornelius IMD Series employs state-of-the-art digital metering technology. This ensures precise control of beverage portions, drastically reducing waste and ensuring consistent drink quality. The technology also allows for real-time tracking of beverage usage, providing valuable insights into inventory management and helping operators understand consumer preferences.

Another important characteristic of the IMD Series is its modular design. This allows operators to configure the unit to suit their specific needs, accommodating everything from carbonated beverages to cold brew coffee and even specialty cocktails. The modular nature also means that upgrades and maintenance can be performed with minimal disruption, keeping downtime to a minimum.

The Cornelius IMD Series is built with energy-efficient components, which is increasingly important in today’s environmentally conscious market. Its design minimizes energy consumption without sacrificing performance, supporting the push for more sustainable business practices.

Furthermore, the IMD Series integrates seamlessly with various payment systems, including cashless options, making transactions smooth and efficient. This integration not only enhances the customer experience but also streamlines the payment process for operators, improving overall service speed.

In conclusion, the Cornelius IMD Series is a versatile beverage dispensing solution that combines innovation, efficiency, and user-friendly design. With its advanced touchscreen interface, precise digital metering, modular construction, energy-efficient operation, and payment integration capabilities, it is poised to revolutionize how beverages are dispensed in various settings, meeting the demands of modern consumers and businesses alike.