CLEANING & CHECKS
Daily Cleaning
1.Remove nozzle assembly and rinse with warm (not hot) water. If possible, soak nozzle assembly over night in carbonated water then rinse with warm water.
Diffuser
Nozzle
2.Wash external surfaces with mild soap solution, rinse with clean water, and wipe dry. Remove the drip tray, wash with mild soap solution, rinse and dry.
NOTE: Do not use abrasive or harsh cleaners on the unit.
Daily Checks
1.Check CO2 supply.
2.Check concentrate supply.
Sanitizing Concentrate Systems
The concentrate systems should be sanitized at least every
IMPORTANT: Only qualified Service Personnel should perform sanitizing procedure on the post- mix
1.Rinse
STEP 1. Wash Concentrate Systems
1.Using a
2.
A.Install bag valves, cut from empty
B.Place all concentrate outlet tubes, with bag valves on their ends, in container containing deter- gent solution.
3.Flush the concentrate system and dispensing valve as follows:
A.Place waste container under applicable dispensing valve.
B.Activate the dispensing valve for one minute to purge all concentrate and flush out the concen- trate system.
4.Repeat the process for each concentrate circuits.
5.Remove detergent solution source from the concentrate system.
STEP 2. Flush Concentrate Systems
Fill
1.Flush detergent solution out of the concentrate system and dispensing valve as follows:
A.Place waste container under applicable dispensing valve.
B.Activate the dispensing valve for one minute to purge all detergent solution and flush out the con- centrate system.
© 2003, IMI Cornelius Inc. | - 7 - | Publication Number: 859000159INS |