INSTALLATION
CAUTION — Only trained and certified electrical, plumbing and refrigeration techni- cians should service this unit. ALL WIRING AND PLUMBING MUST CONFORM TO NATIONAL AND LOCAL CODES.
NOTE: Water pipe connections and fixtures directly connected to the potable water supply must be sized, installed, and maintained in accordance with NSF Standard 18, as well as Federal, State, and Local codes.
NOTE: It is the installer’s responsibility to ensure that the water supply is equipped with protec- tion against backflow. This protection can be an air gap as defined by ANSI/ASME
INSTALLATION REQUIREMENTS
Requirements Summary
Weight: | front or rear counter must be level and able to support 400 lbs. |
Environment: | indoor installation only |
Temperature: | 40 to 110° F ambient temperature |
Clearance: | |
CO2: | 75 psi (5.25 bar) at unit with internal carbonator |
Concentrate: | 60 psi |
Water: | 50 psi maximum |
Electrical: | see nameplate on unit for electrical requirements |
Electrical Requirements
Before connecting electrical power to the unit refer to nameplate to verify power requirements.
DANGER — To avoid possible serious injury or death the ELCB (earth leakage circuit breaker) must be installed in electrical circuit of all 50 Hz units.
WARNING — To avoid possible electrical shock the unit must be electrically grounded using the green grounding screw provided inside the electrical contractor box.
CAUTION — The wiring must be properly grounded and connected through a
ERLY GROUNDED.