Cornelius Non-Carbonated Post-Mix Beverage Dispenser Installation, Requirements Summary

Models: Non-Carbonated Post-Mix Beverage Dispenser

1 20
Download 20 pages 34.37 Kb
Page 6
Image 6
INSTALLATION

Non-Carbonated Impulse Installation & Operations Manual

INSTALLATION

CAUTION — Only trained and certified electrical, plumbing and refrigeration techni- cians should service this unit. ALL WIRING AND PLUMBING MUST CONFORM TO NATIONAL AND LOCAL CODES.

NOTE: Water pipe connections and fixtures directly connected to the potable water supply must be sized, installed, and maintained in accordance with NSF Standard 18, as well as Federal, State, and Local codes.

NOTE: It is the installer’s responsibility to ensure that the water supply is equipped with protec- tion against backflow. This protection can be an air gap as defined by ANSI/ASME A112.1.2-1979, or by an approved vacuum breaker or other approved method.

INSTALLATION REQUIREMENTS

Requirements Summary

Weight:

front or rear counter must be level and able to support 400 lbs.

Environment:

indoor installation only

Temperature:

40 to 110° F ambient temperature

Clearance:

18-inches above

6-inches on sides and rear

CO2:

75 psi (5.25 bar) at unit with internal carbonator

Concentrate:

60 psi

Water:

50 psi maximum

Electrical:

see nameplate on unit for electrical requirements

Electrical Requirements

Before connecting electrical power to the unit refer to nameplate to verify power requirements.

DANGER — To avoid possible serious injury or death the ELCB (earth leakage circuit breaker) must be installed in electrical circuit of all 50 Hz units.

WARNING — To avoid possible electrical shock the unit must be electrically grounded using the green grounding screw provided inside the electrical contractor box.

CAUTION — The wiring must be properly grounded and connected through a 10-amp disconnect switch (slow–blow fuse or equivalent HVAC/R circuit breaker). ALL WIRING MUST CONFORM TO NATIONAL AND LOCAL CODES. MAKE SURE UNIT IS PROP-

ERLY GROUNDED.

Publication Number: 859000159INS

- 2 -

© 2003, IMI Cornelius Inc.

Page 6
Image 6