Cornelius Non-Carbonated Post-Mix Beverage Dispenser Adjusting Flow Rates, Finished Drink oz./sec

Models: Non-Carbonated Post-Mix Beverage Dispenser

1 20
Download 20 pages 34.37 Kb
Page 9
Image 9
Adjusting Flow Rates

Non-Carbonated Impulse Installation & Operations Manual

Adjusting Flow Rates

Flow rates of the water and concentrate are adjusted based on the desired ratio. For example: if the desired ratio is 5:1, then the flow rate of the water is 5 times that of the concentrate.

If the desired finished drink flow rate is 3.0 ounces per second, then the water flow rate is 2.5 oz./sec. and the concentrate flow rate is 0.5 oz./sec. (The water at 2.5 oz./sec. is five times the 0.5 oz./sec. con- centrate flow rate.)

Flow Rates oz./sec. Based on 5:1 Ratio

Finished Drink oz./sec.

Water oz./sec.

Concentrate oz./

sec.

 

 

 

 

 

1.5

1.25

.25

 

 

 

2.0

1.67

.33

 

 

 

2.5

2.08

.42

 

 

 

3.0

2.5

.50

 

 

 

3.5

2.92

.58

 

 

 

4.0

3.33

.67

 

 

 

4.5

3.75

.75

 

 

 

© 2003, IMI Cornelius Inc.

- 5 -

Publication Number: 859000159INS

Page 9
Image 9
Cornelius Non-Carbonated Post-Mix Beverage Dispenser Adjusting Flow Rates, Flow Rates oz./sec. Based on 51 Ratio