Cornelius P/N 630900413 installation instructions Installation Instructions, Bin Stat Kit, P/N

Models: P/N 630000413 P/N 630000408 P/N 630460064 P/N 630900413 P/N 620037008

1 5
Download 5 pages 60.63 Kb
Page 1
Image 1
INSTALLATION INSTRUCTIONS, BIN STAT KIT, P/N 630000408

IMI CORNELIUS INC g One Cornelius Place g Anoka, MN 55303-6234

Telephone (800) 238-3600

Facsimile (800) 535-4321

 

 

 

 

INSTALLATION INSTRUCTIONS, BIN STAT KIT, P/N 630000408

These Bin Stat kits apply to all “I” Series Ice makers

Table 1. Loose–Shipped Parts

Item No.

Part No.

Name

Qty.

1

630900413

Spacer, Hex 5/8” Long x 8–32 SS

1

2

70894

Screw MA 08–32 TRPH 24 SS

1

3

51348

Spacer

1

4

630000413

Thermostat Asy

1

5

620037008

Bin Stat Support

1

6

630460064INS

Installation Instruction, Thermostat

1

7

168833002

Washer SR 4W SS E#8

1

1.Disconnect power.

2.Remove front cover of the unit and the electrical box cover plate.

3.Carefully insert the coiled capillary tube through the bottom hole in the electrical box where the elec- trical wires are coming through (see Figure 4).

4.If there is not a hole already in the chassis base, drill a ½” hole in the chassis base as indicated in Figure 3.

5.Straighten approximately 12” of cap tube to go through hole. Re–coil the remainder. Do not disturb coiled end.

6.Insert the “1/4” diameter wire form support into the coiled end of capillary tube and insert the assem- bly through the hole in the chassis base. Route capillary tube to follow support as closely as pos- sible.

7.Remove the 8–32 nut (closest to the ½” DIA hole) that holds the compartment wall to the base. The adapter kits that have a single level, adapter kits P/N’s 02390, 630200153, 08006, 02388, 08004, 630000191 and 08010) require a 7/8” high spacer be used to mount the binstat support. Thread the 8–32 x 5/8” hex spacer on to the compartment stud. Then fasten the thermostat support to the hex spacer using the ¼” high plastic spacer, #8 flat washer and 8–32 x ¾” long phil. head screw. The spacers are not to be used on the elevated adapter kits. Refer to Figure 2.

8.Any excess capillary tubing must be pulled back into the compressor compartment to prevent ice from damaging it during dispenser operation.

9.Seal ½” diameter hole with sealant (RTV).

March 2, 2004

IMI CORNELIUS INC. 20041Rev A

630460064INS

Page 1
Image 1
Cornelius P/N 630900413 installation instructions Installation Instructions, Bin Stat Kit, P/N, Loose-Shipped Parts, Name