Series 1400"Xtreme"
SPECIFICATIONS OPERATING LIMITS
Model Refrigerant Standard Circuit Maximum Shipping Operating Ambient Water Water Voltage
Number Condenser Type Electrical Capacity Fuse Size Weight Weight Temperature Temperature Pressure Range
XAC1444 Air-Cooled R-404a 208/230/60/1 30 30 317 lbs. 274 lbs. 50°F-100°F 45°F-90°F 20-80 psi 198-253
XWC1444
Water-Cooled
R-404a 208/230/60/1 30 30 295 lbs. 252 lbs. 50°F-100°F 45°F-90°F 20-80 psi 198-253
XRC1444
AC Remote*
R-404a 208/230/60/1 30 30 308 lbs. 265 lbs. 50°F-100°F 45°F-90°F 20-80 psi 198-253
ARI CERTIFIED PERFORMANCE
Ice Harvest Potable Water KWH Condenser
Model Rate Use Consumption Water Use
Number lbs. per 24 hrs. per 100 lbs. per 100 lbs. per 100 lbs.
XAC1444 1275 14.3 6.8 n/a
XWC1444 1374 14.3 5.5 130
XRC1444 1275 14.3 6.8 n/a
Rated in accordance with ARI Standard 810-91.
*Use Remote Condenser CR-1400.
XAC1444/B1048SS
44"73"
32"DIMENSIONS/CAPACITY PLUMBING
Model Nominal Cabinet Water Electrical Service
Number Capacity Dimensions Finish Inlets/Outlets Drainhose Opening
XAC1444 1630 lbs. 44"w x 243⁄4"d x 25"h SS 3⁄8" male flare 9⁄16" I.D. x 3⁄4" O.D. 7⁄8" diameter hole
XWC1444 1505 lbs. 44"w x 243⁄4"d x 25"h SS 3⁄8" male flare 9⁄16" I.D. x 3⁄4" O.D. 7⁄8" diameter hole
XRC1444 1630 lbs. 44"w x 243⁄4"d x 25"h SS 3⁄8" male flare 9⁄16" I.D. x 3⁄4" O.D. 7⁄8" diameter hole
25"
CUBERS8
Series 1200"Xtreme"
ARI CERTIFIED PERFORMANCE
Ice Harvest Potable Water KWH Condenser
Model Rate Use Consumption Water Use
Number lbs. per 24 hrs. per 100 lbs. per 100 lbs. per 100 lbs.
XAC1230 1019 14.6 6.5 n/a
XWC1230 1029 14.6 5.2 79.8
XRC1230 1019 14.6 6.5 n/a
SPECIFICATIONS OPERATING LIMITS
Model Refrigerant Standard Circuit Maximum Shipping Operating Ambient Water Water Voltage
Number Condenser Type Electrical Capacity Fuse Size Weight Weight Temperature Temperature Pressure Range
XAC1230 Air-Cooled R-404a 208-230/60/1 20 20 258 lbs. 229 lbs. 50°F-100°F 45°F-90°F 20-80 psi 198-253
XWC1230
Water-Cooled
R-404a 208-230/60/1 20 20 234 lbs. 205 lbs. 50°F-100°F 45°F-90°F 20-80 psi 198-253
XRC1230 AC Remote* R-404a 208-230/60/1 20 20 247 lbs. 218 lbs. 50°F-100°F 45°F-90°F 20-80 psi 198-253
Rated in accordance with ARI Standard 810-91.
*Use Remote Condenser CR-1200.
DIMENSIONS/CAPACITY PLUMBING
Model Nominal Cabinet Water Electrical Service
Number Capacity Dimensions Finish Inlets/Outlets Drainhose Opening
XAC1230 1177 lbs. 30"w x 241⁄2"d x 28"h SS 3⁄8" male flare 9⁄16" I.D. x 3⁄4" O.D. 7⁄8" diameter hole
XWC1230 1062 lbs. 30"w x 241⁄2"d x 25"h SS 3⁄8" male flare 9⁄16" I.D. x 3⁄4" O.D. 7⁄8" diameter hole
XRC1230 1177 lbs. 30"w x 241⁄2"d x 25"h SS 3⁄8" male flare 9⁄16" I.D. x 3⁄4" O.D. 7⁄8" diameter hole
XAC1230/B1048SS
32"
48"30"
76"
25” (water / remote
cooled)
28" (air-cooled)
PRODUCTION CHART
AIR-COOLED WATER-COOLED REMOTE AIR-COOLED
Water Temperature (˚F) Water Temperature (˚F) Water Temperature (˚F)
Air Temp (˚F) 50 70 80 Air Temp (˚F) 50 70 80 Air Temp (˚F) 50 70 80
50 1177 lbs. 1137 lbs. 1070 lbs. 50 1062 lbs. 1055 lbs. 1042 lbs. 50 1177 lbs. 1137 lbs. 1070 lbs.
70 1143 lbs. 1098 lbs. 1039 lbs. 70 1059 lbs. 1046 lbs. 1027 lbs. 70 1143 lbs. 1098 lbs. 1039 lbs.
90 1076 lbs. 1019 lbs. 977 lbs. 90 1052 lbs. 1029 lbs. 1006 lbs. 90 1076 lbs. 1019 lbs. 977 lbs.
PRODUCTION CHART
AIR-COOLED WATER-COOLED REMOTE AIR-COOLED
Water Temperature (˚F) Water Temperature (˚F) Water Temperature (˚F)
Air Temp (˚F) 50 70 80 Air Temp (˚F) 50 70 80 Air Temp (˚F) 50 70 80
50 1630 lbs. 1505 lbs. 1470 lbs. 50 1505 lbs. 1391 lbs. 1362 lbs. 50 1630 lbs. 1505 lbs. 1470 lbs.
70 1537 lbs. 1416 lbs. 1380 lbs. 70 1473 lbs. 1385 lbs. 1346 lbs. 70 1537 lbs. 1416 lbs. 1380 lbs.
90 1340 lbs. 1275 lbs. 1198 lbs. 90 1409 lbs. 1374 lbs. 1315 lbs. 90 1340 lbs. 1275 lbs. 1198 lbs.