C
U
B
E
R
S
5
Series 300"Xtreme"ARI CERTIFIED PERFORMANCE
Ice Harvest Potable Water KWH Condenser
Model Rate Use Consumption Water Use
Number lbs. per 24 hrs. per 100 lbs. per 100 lbs. per 100 lbs.
XAC322/XAC330 269 16.7 8.5 n/a
XWC322/XWC330 269 16.7 6.8 149
DIMENSIONS/CAPACITY PLUMBING
Model Nominal Cabinet Water Electrical Service
Number Capacity Dimensions Finish Inlets/Outlets Drainhose Opening
XAC322 342 lbs. 22"w x 241⁄2"d x 23"h SS 3⁄8" male flare 9⁄16" I.D. x 3⁄4" O.D. 7⁄8" diameter hole
XAC330 342 lbs. 30"w x 241⁄2"d x 23"hSS 3⁄8" male flare 9⁄16" I.D. x 3⁄4" O.D. 7⁄8" diameter hole
XWC322 334 lbs. 22"w x 241⁄2"d x 23"hSS 3⁄8" male flare 9⁄16" I.D. x 3⁄4" O.D. 7⁄8" diameter hole
XWC330 334 lbs. 30"w x 241⁄2"d x 23"hSS 3⁄8" male flare 9⁄16" I.D. x 3⁄4" O.D. 7⁄8" diameter hole
PRODUCTION CHART
AIR-COOLED WATER-COOLED
Water Temperature (˚F) Water Temperature (˚F)
Air Temp (˚F) 50 70 80 Air Temp (˚F) 50 70 80
50 342 326 312 50 334 302 292
70 338 310 304 70 315 287 285
90 285 269 258 90 299 281 268
SPECIFICATIONS OPERATING LIMITS
Model Refrigerant Standard Circuit Maximum Shipping Operating Ambient Water Water Voltage
Number Condenser Type Electrical Capacity Fuse Size Weight Weight Temperature Temperature Pressure Range
XAC322 Air-Cooled R-404a 115/60/1 20 20 148 lbs. 123 lbs. 50°F-100°F 45°F-90°F 20-80 psi 110-126
XWC322
Water-Cooled
R-404a 115/60/1 20 20 144 lbs. 119 lbs. 50°F-100°F 45°F-90°F 20-80 psi 110-126
XAC330 Air-Cooled R-404a 115/60/1 20 20 163 lbs. 136 lbs. 50°F-100°F 45°F-90°F 20-80 psi 110-126
XWC330
Water-Cooled
R-404a 115/60/1 20 20 155 lbs. 128 lbs. 50°F-100°F 45°F-90°F 20-80 psi 110-126
XAC322/XWC322
Rated in accordance with ARI Standard 810-91.
313⁄4"22"
71"
23"
Series 322†SPECIFICATIONS OPERATING LIMITS
Model Refrigerant Standard Circuit Maximum Shipping Operating Ambient Water Water Voltage
Number Condenser Type Electrical Capacity Fuse Size Weight Weight Temperature Temperature Pressure Range
AC322 Air-Cooled R-404a 115/60/1 20 20 138 lbs. 122 lbs. 50°F-100°F 45°F-90°F 20-120 psi 110-126
WC322
Water-Cooled
R-404a 115/60/1 20 20 134 lbs. 118 lbs. 50°F-100°F 45°F-90°F 20-120 psi 110-126
ARI CERTIFIED PERFORMANCE
Ice Harvest Potable Water KWH Condenser
Model Rate Use Consumption Water Use
Number lbs. per 24 hrs. per 100 lbs. per 100 lbs. per 100 lbs.
AC322 270 23.9 8.7 n/a
WC322 270 23.9 8.7 170
PRODUCTION CHART
AIR-COOLED WATER-COOLED
Water Temperature (˚F) Water Temperature (˚F)
Air Temp (˚F) 50 70 80 Air Temp (˚F) 50 70 80
50 359 lbs. 321 lbs. 312 lbs. 50 341 lbs. 300 lbs. 281 lbs.
70 333 lbs. 313 lbs. 277 lbs. 70 326 lbs. 289 lbs. 266 lbs.
90 305 lbs. 270 lbs. 249 lbs. 90 315 lbs. 270 lbs. 251 lbs.
AC322/B122AP
Rated in accordance with ARI Standard 810-91.
†Limited lifetime warranty does not apply to this model.
22"
29"397⁄8"
DIMENSIONS/CAPACITY PLUMBING
Model Nominal Cabinet Water Electrical Service
Number Capacity Dimensions Finish Inlets/Outlets Drainhose Opening
AC322 359 lbs. 22"w x 231⁄2"d x 163⁄8"hSS 3⁄8" male flare 9⁄16" I.D. x 3⁄4" O.D. 7⁄8" diameter hole
WC322 341 lbs. 22"w x 231⁄2"d x 163⁄8"hSS 3⁄8" male flare 9⁄16" I.D. x 3⁄4" O.D. 7⁄8" diameter hole