C
U
B
E
R
S
C
H
U
N
K
L
E
T
S
9
Series 2448
SPECIFICATIONS OPERATING LIMITS
Model Refrigerant Standard Circuit Maximum Shipping Operating Ambient Water Water Voltage
Number Condenser Type Electrical Capacity Fuse Size Weight Weight Temperature Temperature Pressure Range
IRC2448 AC Remote* R-404a 208-230/60/1 30 30 396 lbs. 335 lbs. 50°F-100°F 50°F-90°F 20-120 psi 198-235
IRC2448-3PH AC Remote* R-404a 208-230/60/3 30 30 396 lbs. 335 lbs. 50°F-100°F 50°F-90°F 20-120 psi 198-235
IWC2448 Water-Cooled R-404a 208-230/60/1 30 30 388 lbs. 327 lbs. 50°F-100°F 50°F-90°F 20-120 psi 198-235

IRC2448/B1048SS

32"
48"
76"
PRODUCTION CHART
REMOTE AIR-COOLED REMOTE WATER-COOLED
Water Temperature (˚F) Water Temperature (˚F)
Air Temp (˚F) 50 70 80 Air Temp (˚F) 50 70 80
50 2460 lbs. 2288 lbs. 2224 lbs. 50 2534 lbs. 2240 lbs. 2138 lbs.
70 2401 lbs. 2244 lbs. 2186 lbs. 70 2500 lbs. 2221 lbs. 2096 lbs.
90 2163 lbs. 2024 lbs. 1938 lbs. 90 2283 lbs. 2200 lbs. 2057 lbs.
DIMENSIONS/CAPACITY
Model Nominal Cabinet
Number Capacity Dimensions Finish
IRC2448 2460 lbs. 48w x 2312"d x 28"h SS
IRC2448-3PH 2460 lbs. 48w x 2312"d x 28"h SS
IWC2448 2534 lbs. 48w x 2312"d x 28"h SS
ARI CERTIFIED PERFORMANCE
Ice Harvest Potable Water KWH Condenser
Model Rate Use Consumption Water Use
Number lbs. per 24 hrs. per 100 lbs. per 100 lbs. per 100 lbs.
IRC2448 2024 15.0 8.0 n/a
IRC2448-3PH 2024 15.0 8.0 n/a
IWC2448 2200 15.0 6.0 135
*Use Remote Condenser CR-2400.
28"

48"

Series 1800"Xtreme"
SPECIFICATIONS OPERATING LIMITS
Model Refrigerant Standard Circuit Maximum Shipping Operating Ambient Water Water Voltage
Number Condenser Type Electrical Capacity Fuse Size Weight Weight Temperature Temperature Pressure Range
XAC1844 Air-Cooled R-404a 208/230/60/1 30 30 367 lbs. 324 lbs. 50°F-100°F 45°F-90°F 20-80 psi 198-253
XWC1844
Water-Cooled
R-404a 208/230/60/1 30 30 345 lbs. 302 lbs. 50°F-100°F 45°F-90°F 20-80 psi 198-253
XRC1844
AC Remote*
R-404a 208/230/60/1 30 30 358 lbs. 315 lbs. 50°F-100°F 45°F-90°F 20-80 psi 198-253
ARI CERTIFIED PERFORMANCE
Ice Harvest Potable Water KWH Condenser
Model Rate Use Consumption Water Use
Number lbs. per 24 hrs. per 100 lbs. per 100 lbs. per 100 lbs.
XAC1844 1600 14.5 7.3 n/a
XWC1844 1610 14.5 6.0 150
XRC1844 1600 14.5 7.3 n/a
Rated in accordance with ARI Standard 810-91.
*Use Remote Condenser CR-2400.

XAC1844/B1048SS

44"
73"
32"
DIMENSIONS/CAPACITY PLUMBING
Model Nominal Cabinet Water Electrical Service
Number Capacity Dimensions Finish Inlets/Outlets Drainhose Opening
XAC1844 1947 lbs. 44"w x 2434"d x 25"h SS 38" male flare 916" I.D. x 34" O.D. 78" diameter hole
XWC1844 1700 lbs. 44"w x 2434"d x 25"h SS 38" male flare 916" I.D. x 34" O.D. 78" diameter hole
XRC1844 1947 lbs. 44"w x 2434"d x 25"h SS 38" male flare 916" I.D. x 34" O.D. 78" diameter hole
25"
PRODUCTION CHART
AIR-COOLED WATER-COOLED REMOTE AIR-COOLED
Water Temperature (˚F) Water Temperature (˚F) Water Temperature (˚F)
Air Temp (˚F) 50 70 80 Air Temp (˚F) 50 70 80 Air Temp (˚F) 50 70 80
50 1947 lbs. 1637 lbs. 1328 lbs. 50 1700 lbs. 1650 lbs. 1610 lbs. 50 1947 lbs. 1637 lbs. 1328 lbs
70 1928 lbs. 1619 lbs. 1309 lbs. 70 1660 lbs. 1630lbs. 1580 lbs. 70 1928 lbs. 1619 lbs. 1309 lbs.
90 1909 lbs. 1600 lbs. 1290 lbs. 90 1640 lbs. 1610 lbs. 1550 lbs. 90 1909 lbs. 1600 lbs. 1290 lbs.