Series 600"Xtreme"
ARI CERTIFIED PERFORMANCE
Ice Harvest Potable Water KWH Condenser
Model Rate Use Consumption Water Use
Number lbs. per 24 hrs. per 100 lbs. per 100 lbs. per 100 lbs.
XAC630 547 16.3 6.9 n/a
XWC630 589 17.4 5.6 116
XRC630 547 16.3 6.9 n/a
SPECIFICATIONS OPERATING LIMITS
Model Refrigerant Standard Circuit Maximum Shipping Operating Ambient Water Water Voltage
Number Condenser Type Electrical Capacity Fuse Size Weight Weight Temperature Temperature Pressure Range
XAC630 Air-Cooled R-404a 208/230/60/1 20 20 201 lbs. 172 lbs. 50°F-100°F 45°F-90°F 20-80 psi 198-253
XWC630
Water-Cooled
R-404a 208/230/60/1 20 20 197 lbs. 168 lbs. 50°F-100°F 45°F-90°F 20-80 psi 198-253
XRC630
AC Remote*
R-404a 208/230/60/1 20 20 209 lbs. 180 lbs. 50°F-100°F 45°F-90°F 20-80 psi 198-253
PRODUCTION CHART
AIR-COOLED WATER-COOLED REMOTE AIR-COOLED
Water Temperature (˚F) Water Temperature (˚F) Water Temperature (˚F)
Air Temp (˚F) 50 70 80 Air Temp (˚F) 50 70 80 Air Temp (˚F) 50 70 80
50 722 lbs. 648 lbs. 634 lbs. 50 671 lbs. 603 lbs. 556 lbs. 50 722 lbs. 648 lbs. 634 lbs.
70 672 lbs. 609 lbs. 589 lbs. 70 661 lbs. 594 lbs. 551 lbs. 70 672 lbs. 609 lbs. 589 lbs.
90 606lbs. 547 lbs. 521 lbs. 90 652 lbs. 589 lbs. 542 lbs. 90 606 lbs. 547 lbs. 521 lbs.

XAC630/B530AP

*Use Remote Condenser CR-800.
Rated in accordance with ARI Standard 810-91.
25"
325
16"

30"

73"
DIMENSIONS/CAPACITY PLUMBING
Model Nominal Cabinet Water Electrical Service
Number Capacity Dimensions Finish Inlets/Outlets Drainhose Opening
XAC630 722 lbs. 30"w x 2412"d x 25"h SS 38" male flare 916" I.D. x 34" O.D. 78" diameter hole
XWC630 671 lbs. 30"w x 2412"d x 25"h SS 38" male flare 916" I.D. x 34" O.D. 78" diameter hole
XRC630 722 lbs. 30"w x 2412"d x 25"h SS 38" male flare 916" I.D. x 34" O.D. 78" diameter hole
C
U
B
E
R
S
6
Series 500"Xtreme"
ARI CERTIFIED PERFORMANCE
Ice Harvest Potable Water KWH Condenser
Model Rate Use Consumption Water Use
Number lbs. per 24 hrs. per 100 lbs. per 100 lbs. per 100 lbs.
XAC522/XAC530 475 17.0 6.7 n/a
XWC522/XWC530 475 17.0 5.8 133
XRC522/XRC530 475 17.0 6.7 n/a
DIMENSIONS/CAPACITY PLUMBING
Model Nominal Cabinet Water Electrical Service
Number Capacity Dimensions Finish Inlets/Outlets Drainhose Opening
XAC522 600 lbs. 22"w x 2412"d x 23"h SS 38" male flare 916" I.D. x 34" O.D. 78" diameter hole
XWC522 600 lbs. 22"w x 2412"d x 23"hSS 38" male flare 916" I.D. x 34" O.D. 78" diameter hole
XRC522 540 lbs. 22"w x 2412"d x 23"hSS 38" male flare 916" I.D. x 34" O.D. 78" diameter hole
XAC530 540 lbs. 30"w x 2412"d x 23"hSS 38" male flare 916" I.D. x 34" O.D. 78" diameter hole
XWC530 600 lbs. 30"w x 2412"d x 23"hSS 38" male flare 916" I.D. x 34" O.D. 78" diameter hole
XRC530 600 lbs. 30"w x 2412"d x 23"hSS 38" male flare 916" I.D. x 34" O.D. 78" diameter hole
SPECIFICATIONS OPERATING LIMITS
Model Refrigerant Standard Circuit Maximum Shipping Operating Ambient Water Water Voltage
Number Condenser Type Electrical Capacity Fuse Size Weight Weight Temperature Temperature Pressure Range
XAC522 Air-Cooled R-404a 115/60/1 20 20 162 lbs. 135 lbs. 50°F-100°F 45°F-90°F 20-80 psi 110-126
XWC522
Water-Cooled
R-404a 115/60/1 20 20 145 lbs. 117 lbs. 50°F-100°F 45°F-90°F 20-80 psi 110-126
XRC522
AC Remote*
R-404a 115/60/1 20 20 165 lbs. 141 lbs. 50°F-100°F 45°F-90°F 20-80 psi 110-126
XAC530 Air-Cooled R-404a 115/60/1 20 20 170 lbs. 143 lbs. 50°F-100°F 45°F-90°F 20-80 psi 110-126
XWC530
Water-Cooled
R-404a 115/60/1 20 20 153 lbs. 125 lbs. 50°F-100°F 45°F-90°F 20-80 psi 110-126
XRC530
AC Remote*
R-404a 115/60/1 20 20 180 lbs. 149 lbs. 50°F-100°F 45°F-90°F 20-80 psi 110-126

XAC522/XAC530

Rated in accordance with ARI Standard 810-91.
23"
32516"
30"
61"
PRODUCTION CHART
AIR-COOLED WATER-COOLED REMOTE AIR-COOLED
Water Temperature (˚F) Water Temperature (˚F) Water Temperature (˚F)
Air Temp (˚F) 50 70 80 Air Temp (˚F) 50 70 80 Air Temp (˚F) 50 70 80
50 600 596 542 50 540 515 489 50 600 596 542
70 597 549 536 70 540 494 475 70 597 549 536
90 513 475 454 90 532 475 454 90 513 475 454
* Use Remote Condenser CR-500.