Image 10
CLEANING AND SANITIZING

Continuous Flow Icemaker Service Manual

CLEANING AND SANITIZING

ICEMAKER CLEANING AND SANITIZING PROCEDURES

Do not use any of the ice made during cleaning operations.

Clean and sanitize ice storage area when cleaning icemaker.

1.Turn off machine.

2.Shut off water supply

3.Remove ice from storage bin.

4.Mix approved cleaner (4 gallons as directed). Recommended cleaner: Calgon Nickel-Safe, ice

machine cleaner. Mixture: 3 ounces per gallon of water.

5.Clean auger/diverter assembly and ice transition/drop tube in a sink using cleaner mixture and reinstall in icemaker. Using cleaner, wipe down dispense tray.

6.Turn machine on and add cleaner solution to water level control, 2 gallons to each control.

7.Turn on water supply and run machine for 15 minutes.

8.Turn off machine and remove all ice. Turn off water and drain water.

9.Sanitize using household liquid bleach (299 ppm chlorine). Mixture: ½ fluid ounce per gallon room temperature water. 2 minute exposure time.

10.Sanitize auger/diverter assembly and ice transition/drop tube in a sink using sanitizing solution and reinstall in icemaker. Using sanitizer, wipe down dispense tray.

11.Fill icemaker with sanitizer by slowly pouring solution into water feed reservoir until full. Solution will drain through overflow tube. Turn on water. Run the icemaker for 15 minutes. Turn off ice machine and remove all ice.

12.If icemaker is used in conjunction with ice dispenser or storage bin, follow manufacturer’s recommended cleaning instructions at this time.

MAINTENANCE

Preventive maintenance can increase the trouble free life of your icemaker. Many authorized service agencies offer service contracts for your icemaker. Contact your local distributor for further information.

Monthly

1.Clean the condenser. Use a brush, vacuum cleaner or blower from inside with air or CO2 gas.

2.Inspect water feed reservoir at least once a month until a definite pattern for cleaning and sanitizing has bee established.

Quarterly

This is the maximum period of time between cleaning and sanitizing the icemaker. In addition to rec- ommended monthly procedure, and if a more frequent cleaning and sanitizing pattern has not been established, unit must be cleaned and sanitized.