Coway CHP-04AU Water Filtration System Performance Data Sheet, Brand Metro, Model CHP-04AR

Models: CHP-04AR CHP-04AU

1 44
Download 44 pages 15.2 Kb
Page 31
Image 31
Water Filtration System Performance Data Sheet

Water Filtration System Performance Data Sheet

Brand: Metro

Model: CHP-04AR

This system has been tested and certified by the Water Quality Association according to NSF/ANSI 42, 53, and 58 for the reduction of the substances listed below. The concentration of the indicated substances in water entering the system was reduced to a concentration less than or equal to the permissible limit for water leaving the system, as specified in NSF/ANSI 42, 53, and 58.

 

Max. Allowable

Average

Average

Minimum

Average

Substance

Concentration

Influent

Effluent

Percent

Percent

 

(mg/L)

(mg/L)

(mg/L)

Reduction (%)

Reduction (%)

Arsenic (Pentavalant)

0.010

0.05

0.006

79.1

87.7

Barium

2.0

10

1.4

83.5

86.6

Radium 226/228

5pCi/L

25pCi/L

5pCi/L

N/A

N/A

Cadmium

0.005

0.031

0.002

89.0

92.7

Chromium (Hexavalent)

0.1

0.358

0.023

93.8

95.1

Chromium (Trivalent)

0.1

0.367

0.028

93.8

95.7

Lead

0.010

0.153

0.005

93.6

95.1

Nitrate/Nitrite

10

29.6

4.8

78.5

83.7

Selenium

0.05

0.117

0.003

96.0

97.8

TDS

<187.5

741.5

14.5

97.3

98.0

Aesthetic Chlorine

 

 

 

 

 

INNOSENSE

≥ 50%

2.07

0.56

54.53

72.8

FINE POST CARBON

≥ 50%

1.96

0.53

55.0

72.8

VOC*

 

 

 

 

 

INNOSENSE

≥ 95% reduction

0.327

0.0052

96.20

98.4

FINE POST CARBON

≥ 95% reduction

0.317

0.005

96.2

98.5

While testing was performed under laboratory conditions, actual performance may vary.

General Operating Information:

 

INNOSENSE FILTER

359 gallons (for VOC)

 

7,523 gallons (for Aesthetic Chlorine)

Rated Capacity

 

POST-CARBON FILTER

402 gallons (for VOC)

 

 

1,453 gallons (for Aesthetic Chlorine)

 

 

Min-Max operating pressure:

10 ~ 120 psi (0.7 ~ 8.4 kgf/cm2)

Min-Max feed water temperature:

41 ~ 95 ºF (5 ~ 35 ºC)

Rated Service Flow

0.07 GPM (for VOC)

0.5 GPM (for Aesthetic Chlorine)

 

 

Daily Water Production Rate

86.2 GPD

Product Efficiency Rating

38.7 %

Electrical Requirements:

120 Vac / 60Hz

Do not use with water that is microbiologically unsafe or of unknown quality without adequate disinfection before or after the system.

Refer to the owners manual for specific installation instructions, manufacturer’s limited warranty, user responsibility, and parts and service availability.

The influent water to the system shall include the following characteristics: o No organic solvents

o Chlorine: < 2 ppm

o pH: 7 - 8

o Temperature: 41 ~ 95 ºF (5 ~ 35 ºC)

o Iron: < 2 ppm

o Turbidity: < 1 NTU

o Hardness: < 1000 mg/L

LOthers WATER TERDIFAGRA MOW / MPERFORD ANCE ATA SHEET CHP-04AR

30

Page 31
Image 31
Coway CHP-04AU Water Filtration System Performance Data Sheet, Brand Metro, General Operating Information, Model CHP-04AR