Coway CHP-04AL, CHP-04AU, CHP-04AR warranty Maintenance DL ILF METHOTER MENTREP ACE

Models: CHP-04AR CHP-04AU

1 44
Download 44 pages 15.2 Kb
Page 27
Image 27
Maintenance DL ILF METHOTER MENTREP ACE

3. After separating the fitting connected to the filter to replace, please replace the filter..(Separate the fitting using the proper tool..)

 

When you are replacing filters, please make sure that a corresponding filter and a

Tips

hose are firmly connected and that there is no leakage.

It is recommended to empty the water tank filled with the filtered water at least one

 

 

time right after the filter replacement.

4. Please fit the groove of the front cover.. After tightening 1 fixed screw in the front draining part using the Phillips driver, let down and close the front draining door..

Manual background Before installing a new filter, please do the filter cleansing first as directed below:

Tips

Filter Name

Cleansing Time

Comment

 

Plus sediment filter

30 seconds

 

 

 

 

 

 

Pre-carbon / Inno-

 

 

 

sense / Post carbon

3 minutes

Please use plus sediment filtered water for

 

/ Fine post carbon

cleansing

 

 

 

filter

 

 

 

 

 

 

 

Ro membrane filter

3 minutes

Please use plus sediment filtered water for

 

cleansing

 

 

 

 

 

 

 

Maintenance DL ILF METHOTER MENTREP ACE