7

A

B

51
Important
- Clean the drainpipe every 6 months in case drain (B) is used.
- The water still being in the drain needs to be drained using drain (A) before
cleaning the drainpipe or replacing the exhaust valve.
Verify that the belts are running in the middle of the basket pulley.
Verify the belt tension according to the table below. Belt tension measurements
should be taken as close as possible to the center of the belt span (see gure).
Annual maintenance
Belt tension:
Belt tension testing table
Model Belt Frequency (Hz) Tension force (N) Deection (mm) Deection force
MIN
MAX
MIN
MAX
at MIN
tension
at MAX
tension
MAX
HC60 8PJ 1355 107 137 470 766 7 4 40
HC65 8PJ 1355 107 137 470 766 7 4 40
HC75 8PJ 1355 107 137 470 766 7 4 40
HC100 8PJ 1355 107 137 470 766 7 4 40
HC135 10J 1473 75 105 316 618 10,5 6,4 40
HC165 10J 1473 75 105 316 618 10,5 6,4 40
1 Deection
2 Span length