4

WARNING

The washer-extractor should be connected to an individual branch circuit not shared with lighting or other equipment.

Electrical Specifications HC165, IHC035, CHC035, IHC165

165 liters / 35 pounds

 

 

 

 

 

Boiler Fed/Steam Heat

 

Electric Heat

 

Code

Voltage

Cycle

Phase

Wire

Full Load Amps

 

Recommended Circuit Breaker (US-market)

AWG/mm2

kW Standard Heating Elements

Full Load Amps

 

Recommended Circuit Breaker (US- market)

AWG/mm2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

US

NON-US

 

 

 

US

 

NON-US

 

N

440-480

50/60

3

3+PE

6

15

10

14/2.5

 

32

40

 

40

8/10.0

P

380-415

50/60

3

3+N+PE

18

20

20

12/4.0

6x3 kW

44

50

 

50

8/10.0

Q

200-240

50/60

3

3+PE

18

20

20

12/4.0

63

70

 

70

4/25.0

 

 

X

200-240

50/60

1/3

2/3+PE

18

20

20

12/4.0

 

63

70

 

70

4/25.0

 

 

 

 

 

 

 

 

 

Alternative Electric Heat Options

N

440-480

50/60

3

3+PE

 

 

 

 

 

23

30

 

32

10/6.0

P

380-415

50/60

3

3+N+PE

 

 

 

 

6x2 kW

36

40

 

40

8/10.0

Q

200-240

50/60

3

3+PE

 

 

 

 

49

60

 

60

6/16.0

 

 

 

 

 

 

X

200-240

50/60

1/3

2/3+PE

 

 

 

 

 

N/A

N/A

 

N/A

N/A

N

440-480

50/60

3

3+PE

 

 

 

 

 

28

40

 

40

8/10.0

P

380-415

50/60

3

3+N+PE

 

 

 

 

3x3 kW +

40

50

 

50

8/10.0

Q

200-240

50/60

3

3+PE

 

 

 

 

3x2 kW

56

60

 

60

6/16.0

X

200-240

50/60

1/3

2/3+PE

 

 

 

 

 

56

60

 

60

6/16.0

N

440-480

50/60

3

3+PE

 

 

 

 

 

36

40

 

40

8/10.0

P

380-415

50/60

3

3+N+PE

 

 

 

 

3x3 kW +

49

60

 

60

6/16.0

Q

200-240

50/60

3

3+PE

 

 

 

 

3x4 kW

N/A

N/A

 

N/A

N/A

X

200-240

50/60

1/3

2/3+PE

 

 

 

 

 

N/A

N/A

 

N/A

N/A

N

440-480

50/60

3

3+PE

 

 

 

 

 

41

50

 

50

8/10.0

P

380-415

50/60

3

3+N+PE

 

 

 

 

6x4 kW

53

60

 

60

6/16.0

Q

200-240

50/60

3

3+PE

 

 

 

 

N/A

N/A

 

N/A

N/A

 

 

 

 

 

 

X

200-240

50/60

1/3

2/3+PE

 

 

 

 

 

N/A

N/A

 

N/A

N/A

 

 

 

 

 

 

 

Table 7

 

 

 

 

 

 

 

44

Page 44
Image 44
Alliance Laundry Systems HC75, HC65, HC135, HC60 Electrical Specifications HC165, IHC035, CHC035, IHC165, Liters / 35 pounds