Steam connection

5

WARNING

Never touch internal or external steam pipes, connections, or components. These surfaces can be extremely hot and will cause severe burns. The steam must be turned off and the pipe, connections, and components allowed to cool before the pipe can be touched.

Machines with steam heating must have a steam valve between the steam installation and the machine.

5

3

4

3

2

1

 

 

 

6

 

 

 

 

 

 

 

 

 

 

 

 

 

7

With direct steam injection into the machine (See Table 8)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1.

Steam pipe

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2.

Steam cut-off valve

 

 

 

 

 

 

 

3.

Pipe coupling

 

 

 

 

 

 

 

4.

Steam filter

 

 

 

 

 

 

 

5.

Magnetic steam valve

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

7

6.

Curve MF

 

 

 

 

 

7.

Steam hose with appropriate pipe coupling

 

 

 

 

 

 

 

 

 

 

7

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Steam Supply Information

MODEL

Steam inlet connection, inch

Number of steam inlets

Recommended pressure, bar

Recommended pressure, psi

Maximum pressure, bar

Maximum pressure, psi

 

 

 

 

 

 

 

 

For the HC60, IHC012, IHC060

3/8

1

2.0 - 5.5

30 - 80

5.5

80

For the HC65, IHC014, IHC065

3/8

1

2.0 - 5.5

30 - 80

5.5

80

For the HC75, IHC018, CHC018, IHC075

3/8

1

2.0 - 5.5

30 - 80

5.5

80

For the HC100, IHC025, CHC025, IHC100

3/8

1

2.0 - 5.5

30 - 80

5.5

80

For the HC135, IHC030, IHC135

3/8

1

2.0 - 5.5

30 - 80

5.5

80

For the HC165, IHC035, CHC035, IHC165

3/8

1

2.0 - 5.5

30 - 80

5.5

80

Table 8

48

Page 48
Image 48
Alliance Laundry Systems HC65, HC165, HC75, HC135 Steam connection, With direct steam injection into the machine See Table