BATTERY | PACK/CHARGER |
|
|
|
|
|
| [] | If both | yellow | and green LED come | on, this |
| ||||||||||||||||
The battery | pack | and charger are not included | with |
| indicates a deeply | discharged | or defective | battery | |||||||||||||||||||||
your worklight. They are both sold separately. When |
| pack. |
|
|
|
|
|
|
|
|
|
|
|
| |||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||||||||||||||
purchasing, | use the following | information: |
|
|
|
| Allow battery pack to remain | in charger for 15 to | |||||||||||||||||||||
MODEL | NO. |
| BATTERY PACK | CHARGER |
|
| 30 minutes. When battery pack reaches normal | ||||||||||||||||||||||
973.113911 |
| item No. _911375 | item | No. _911041 |
| voltage | range, red LED should come on. |
|
| ||||||||||||||||||||
|
|
|
| (1323517 or 1323903) | (1425301) |
| If red LED does not come | on after 30 minutes, | this | ||||||||||||||||||||
BATTERY | PACK |
|
|
|
|
|
|
|
| indicates a defective |
| battery | pack and should | be | |||||||||||||||
The battery | pack | for your worklight | has been shipped |
| replaced. |
|
|
|
|
|
|
|
|
|
|
| |||||||||||||
in a low charge | condition | to | prevent | possible | prob- | [] | After normal | usage, | a minimum | of 1 hour | of |
| |||||||||||||||||
lems. Therefore, | you should | charge | it until light | on |
| charging time | is required to fully | recharge | battery | ||||||||||||||||||||
front | of charger | changes | from red to green. |
|
|
| pack. |
|
|
|
|
|
|
|
|
|
|
|
| ||||||||||
Note: Batteries | will not reach full charge the first time | [] | The battery | pack | will | become | slightly warm to | the | |||||||||||||||||||||
they | are charged. | Allow | several | cycles (operating |
| touch while | charging. | This | is normal | and does | not | ||||||||||||||||||
worklight | followed | by recharging) for batteries | to |
| indicate | a problem. |
|
|
|
|
|
|
|
| |||||||||||||||
become | fully | charged. |
|
|
|
|
|
|
| [] | Do not | place charger | and | battery pack in an area | |||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||||||||||||||||
CHARGING |
| BATTERY | PACK |
|
|
|
|
| of extreme | heat or cold. It will work | best at normal | ||||||||||||||||||
See Figure | 1. |
|
|
|
|
|
|
|
|
|
| room temperature. |
|
|
|
|
|
|
|
|
| ||||||||
|
|
|
|
|
|
|
|
|
| Note: Charger and battery pack should be placed | |||||||||||||||||||
[] | Use only the | recommended | battery pack | and |
| ||||||||||||||||||||||||
| in a location where the temperature is more than | ||||||||||||||||||||||||||||
| charger | with | your worklight. |
|
|
|
|
|
| ||||||||||||||||||||
|
|
|
|
|
|
| 50°F but less than 100°R |
|
|
|
|
|
| ||||||||||||||||
[] | Make sure | power supply | is normal | household |
|
|
|
|
|
|
| ||||||||||||||||||
[] | When batteries become fully | charged, unplug |
| ||||||||||||||||||||||||||
| voltage, | 120 volts, | 60 Hz, | AC only. |
|
|
|
| |||||||||||||||||||||
|
|
|
|
| charger from power supply and remove the bat- | ||||||||||||||||||||||||
[] | Connect |
| charger to power | supply. |
|
|
|
| |||||||||||||||||||||
|
|
|
|
| tery pack. |
|
|
|
|
|
|
|
|
|
|
| |||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||||
[] | Place battery | pack in charger aligning | raised | iNFORMATION |
| FOR | RECHARGING | HOT |
| ||||||||||||||||||||
| rib on battery pack with groove in charger. |
|
|
|
| ||||||||||||||||||||||||
|
|
| BATTERY | PACK |
|
|
|
|
|
|
|
|
| ||||||||||||||||
| See Figure | 1. |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||||||
[] | Press down | on battery pack to be sure contacts | When | using your | worklight continuously, | the batteries | |||||||||||||||||||||||
| on battery pack engage properly with | contacts in | in your | battery | pack will | become | hot. You should let a | ||||||||||||||||||||||
| charger. |
|
|
|
|
|
|
|
|
|
|
| hot battery | pack | cool down for approximately | 30 min- | |||||||||||||
[] | Normally, | the red LED on charger will come | on. | utes before attempting to recharge. When the battery | |||||||||||||||||||||||||
pack becomes discharged and is hot, this will cause | |||||||||||||||||||||||||||||
| This indicates charger is in fast charging mode. | ||||||||||||||||||||||||||||
| the green LED to come on instead of the red LED. |
| |||||||||||||||||||||||||||
[] | Red LED should remain | on for approximately | 1 |
| |||||||||||||||||||||||||
After 30 minutes, reinsert battery pack in charger. If | |||||||||||||||||||||||||||||
| hour then the green LED will come on. Green LED | ||||||||||||||||||||||||||||
| green LED continues to remain on, return battery pack | ||||||||||||||||||||||||||||
| on indicates battery pack is fully charged and | ||||||||||||||||||||||||||||
| to your nearest Sears Repair Center for checking or | ||||||||||||||||||||||||||||
| charger is in trickle charge mode. Note: Green | ||||||||||||||||||||||||||||
| replacing. |
|
|
|
|
|
|
|
|
|
|
|
| ||||||||||||||||
| LED will remain on until battery pack is removed |
|
|
|
|
|
|
|
|
|
|
|
| ||||||||||||||||
| Note: This situation only occurs when continuous |
| |||||||||||||||||||||||||||
| from charger or charger is disconnected from |
| |||||||||||||||||||||||||||
| use of your worklight causes the batteries to become | ||||||||||||||||||||||||||||
| power supply. |
|
|
|
|
|
|
| |||||||||||||||||||||
|
|
|
|
|
|
|
| hot. It does not occur under normal circumstances. |
| ||||||||||||||||||||
|
|
|
|
|
|
|
|
|
| BATTERYPACK |
| ||||||||||||||||||
|
|
|
|
|
|
|
|
|
| Refer to "CHARGING | BATTERY | PACK" | for normal | ||||||||||||||||
|
|
|
|
|
|
|
|
|
| SHOWNIN CHARGER | recharging | of batteries. | If the charger does not charge |
| your battery pack under normal circumstances, return | |
CHARGER | both the battery pack and charger to your nearest | |
Sears Repair Center for electrical check. | ||
|
REDLED ON INDICATES
FASTCHARGINGMODE
GREENLEDON AFTERFAST CHARGING
CYCLE,iNDICATESFULLYCHARGEDBATTERY
PACKANDIN TRICKLECHARGEMODE.
YELLOWANDGREENLED8
ON INDICATESDEEPLY
Fig. 1