Service Air Cleaner
Your engine will not run properly and may be damaged if you run it using a dirty air cleaner. Clean or replace the air cleaner paper filter once every
50 hours of operation or once a year, whichever comes first. Clean or replace more often if operating under dusty or dirty conditions. Clean foam precleaner every 25 hours of operation or sooner under dusty conditions.
To clean or replace foam precleaner:
•Remove air cleaner cover, then the foam
Foam
Paper
Filter
•Wash precleaner in soapy water. Squeeze
•Clean air cleaner cover before installing it.
To clean or replace paper air filter:
•Remove air cleaner cover; then remove foam pre- filter (service if necessary) and remove paper filter.
•Clean paper filter by tapping it gently on a solid surface. If the filter is too dirty, replace it with a new one. Dispose of the old filter properly.
•Clean air cleaner cover then insert precleaner into cover. Next insert new paper filter into cover to
hold precleaner in place and assemble all of them to the base of the air cleaner.
NOTE: If you need to order a new air filter, please call
Clean Spark Arrester Screen
The engine exhaust muffler includes a spark arrester screen. Inspect and clean the screen every 100 hours of operation or once each year, whichever comes first.
NOTE: If you use your generator on any forest- covered,
Clean and inspect the spark arrester screen as follows:
•To remove the heat shield from the muffler, remove the screws that connect the shield to the muffler.
•Remove the screws that attach the spark arrester screen.
SPARK ARREST E R
SCREEN
MUFFLER
HEAT SHIELD
•Inspect screen and replace if torn, perforated or otherwise damaged. Do Not use a defective screen. If screen is not damaged, clean it with commercial solvent.
•Reattach the screen and the heat shield.
13