SECTION: A - PUMP SPECIFICATIONS
DISCHARGE | 8” NPT, 125 lb. Flange Horizontal |
LIQUID TEMPERATURE ... | 104°F (40°C) Continuous |
VOLUTE | Cast Iron ASTM |
| with Cast Iron Wear Ring |
MOTOR HOUSING | Cast Iron ASTM |
SEAL PLATE | Cast Iron ASTM |
IMPELLER: | 3 Vane, Enclosed with Bronze wear |
Design | |
| ring and pump out vanes on back |
| side. Dynamically Balanced ISO |
| G6.3 |
Material | Cast Iron ASTM |
SHAFT | 416 Stainless Steel |
SQUARE RINGS | |
HARDWARE | 300 Series Stainless Steel |
LIFTING CHAIN | Yoke, Galvanized |
PAINT | Air Dry Enamel. |
SEAL: Design | Tandem Mechanical, Oil Filled |
| Reservoir. |
Material | Rotating Faces - Carbone |
| Stationary Faces - Ceramic |
| Elastomer - |
| Hardware |
CORD ENTRY | 25 ft. (7.6 m) Std. Cord. Epoxy |
| Sealed Housing with Secondary |
| Pressure Grommet for Sealing and |
| Strain Relief |
SPEED | 870, 1150, 1750 RPM (Nominal) |
UPPER BEARING: | Single Row, Ball, Grease Lubricated |
Design | |
Load | Radial |
LOWER BEARING: | Double Row, Ball, Grease Lubricated |
Design | |
Load | Radial & Thrust |
MOTOR: Design | NEMA B, Three Phase Torque Curve |
| |
| “UL” Listed for Class I, Groups C & |
| D, Division 1, Explosion Proof |
Insulation | Class F. |
SINGLE PHASE | Capacitor Start/Induction Run. |
| Start Capacitors included with |
| pump assembly. Controls require |
| external overload protection. |
THREE PHASE | Dual Voltage 230/460; Requires |
| Overload Protection to be Included |
| in control panel. |
MOISTURE SENSOR | Normally Open (N/O), Requires |
| Relay in Control Panel |
TEMP SENSOR | Normally Closed (N/C), Requires |
Relay in Control Panel
OPTIONAL EQUIPMENT: Seal Material, Impeller Trims,
Additional Cord
inches
(mm)
8XSE20048HA - 49.06 (1246) 8XSE20058HA - 49.06 (1246) 8XSE25048HA - 49.06 (1246) 8XSE25058HA - 49.06 (1246) 8XSE30048HA - 49.06 (1246) 8XSE30058HA - 49.06 (1246) 8XSE30046HA - 49.06 (1246) 8XSE30056HA - 49.06 (1246) 8XSE40046HA - 49.06 (1246) 8XSE40056HA - 49.06 (1246) 8XSE50046HA - 49.06 (1246) 8XSE50056HA
8XSE100044HA - 54.50 (1384) 8XSE100054HA - 54.50 (1384) 8XSE125044HA - 54.50 (1384) 8XSE125054HA - 54.50 (1384) 8XSE150044HA - 54.50 (1384) 8XSE150054HA - 54.50 (1384)
IMPORTANT !
1.) MOISTURE AND TEMPERATURE SENSORS MUST BE CONNECTED TO VALIDATE THE UL LISTING.
2.) A
3.) A SPECIAL MOISTURE SENSOR RELAY IS REQUIRED IN THE CONTROL PANEL FOR PROPER OPERATION OF THE MOISTURE SENSORS. CONTACT BARNES PUMPS FOR INFORMATION CONCERNING MOISTURE SENSING RELAYS FOR CUSTOMER SUPPLIED CONTROL PANELS.
4.) THESE PUMPS ARE UL LISTED FOR PUMPING WATER AND WASTEWATER. DO NOT USE TO PUMP FLAMMABLE LIQUIDS.
5.) INSTALLATIONS SUCH AS DECORATIVE FOUNTAINS OR WATER FEATURES PROVIDED FOR VISUAL ENJOYMENT MUST BE INSTALLED IN ACCORDANCE WITH THE NATIONAL ELECTRIC CODE ANSI/NFPA 70 AND/OR THE AUTHORITY HAVING JURISDICTION. THIS PUMP IS NOT INTENDED FOR USE IN SWIMMING POOLS, RECREATIONAL WATER PARKS, OR INSTALLATIONS IN WHICH HUMAN CONTACT WITH PUMPED MEDIA IS A COMMON OCCURRENCE.