Creda NPP100S 75-773012 dimensions Bathroom Installation, Wall Mounting, For all heater sizes

Models: NP150 75-772903 NP200 75-772904 NP50 75-772901 NPP150 75-773003 NPP100 75-773002 NP100 75-772902 NPP200S 75-773014 NPP150S 75-773013 NPP50 75-773001 NPP100S 75-773012 NPP200 75-773004 NPP50S 75-773011

1 4
Download 4 pages 59.13 Kb
Page 2
Image 2
Bathroom Installation

Bathroom Installation

IMPORTANT – If the heater is installed in a room containing a bath or shower, it must be so installed that switches and other controls cannot be touched by a person using a bath or shower.

Wall Mounting

IMPORTANT – DO NOT locate the heater immediately below a fixed socket outlet or connection box. The wall bracket supplied with the appliance should be fitted using the screws and wall plugs provided. The heater should be positioned observing the minimum clearances around the heater (see diagram C).

For all heater sizes

The bracket has been designed to be used as a template for setting the wall fixing position. Refer to the diagrams below for dimensional details. To set the vertical minimum, the bracket should be positioned on the floor and the wall marked at the notches in the vertical members of the bracket. This marks the final position of the bottom of the bracket. When placing the heater on the bracket, firstly engage the heater on to the bottom hooks and then press the heater on to the catches. It is recommended to press the heater at the ends and not on the grille area.

500W Heater (refer to diagram A)

If the heater is required to be fitted towards an object/obstruction to the left then the bracket should be positioned against the floor and the object/obstruction and the wall marked along the right edge of the right upright. This is the final position of the left side of the left upright member of the bracket.

If the heater is required to be fitted towards an object/obstruction to the right then the bracket should be positioned against the floor and the object/obstruction and the wall marked along the left edge of the left upright. This is the final position of the right side of the right upright member of the bracket.

All other sizes of heaters (refer to diagram B)

If the heater is required to be fitted towards an object/obstruction to the left then the bracket should be positioned against the floor and the object/obstruction and the wall marked at notch ‘A’. This is the final position of the left side of the left upright member of the bracket.

If the heater is required to be fitted towards an object/obstruction to the right then the bracket should be positioned against the floor and the object/obstruction, and the wall marked at notch ‘B’. This is the final position of the right side of the right upright member of the bracket.

The bracket has also been designed to allow the use of a spirit level on the horizontal member for levelling during fitting.

Final bracket position

Page 2