Installation Instructions
Temperature-Pressure
Relief Valve
_WARNING
At the time of manufacturethiswater heaterwasprovidedwith a combinatien temperamre_resseresretief valveearthed by a nationally recognizedtestinglaboratorythat maintainsperiodic
inspectionof productionof li_.. equipmentor materials,as meetingthe _luirements for RehefValvesand AutomaticGas
ShutoffDevicesfor Hot Water SupplySystems,and the latest editionof ANSI 7.21.22and rite coderequirementsof ASME.If replaced,the valvemustmeet the requirementsof localcedes, but not lessthan a combinationtemperatureand pressurerelief valvecertifiedas meetingthe requirementsfor ReliofValvesand AutomaticGasShutoff Devicesfor Hot Water SupplySysten_, ANSI Z21.22 by a nationallyrecognizedtestinglaboratorythat
mdnt_ per;oakim4_'t_ of preduct_of ,stedequ_=nt
or material_
The valvemust be marked with a maximum set pressurenot to exceed the marked hydrostaticworking pressureof the water heater (150 IbsJsq.in.) and a dischargecapEt'm/nut lessthan the water heater input rate as shownon the model rating plate. (Electric heaters - watts dividedby 1000x 3415 equal BTU/Hr. rate.)
YourlocaljurirKl_ anthorit_ whilemandatingthe useof a
Compliancewith suchlocalrequirementsmust be satisfiedby the installeror end userof the water heaterwith a locallypre-
nated openingin the water heater in placeof the factory fur- nishedvalve.
For safeoperationof the water heater,the reliefvalvemustnot beremovedfrom it'sdesignatedopeningor plugged.
The
chargewill exit onlywithin 6 inches above,or at any distance belowthe structuralfloor.Be certainthat no contact ismade
with anyliveelectricalpart.The dischargeopeningmust not be blockedor reducedin size underany circumstancesExcessive. length,over30 feet, or useof more than fourelbowscan cause restrictionand reducethe dischargecapacityofthe valve.
No valveor other obstructionisto be placedbetweenthe relief valveand the tank. Do not connecttubingdirectlyto discharge drain unless a 6" air gap is provided.To preventbodilyinjury,
hazard to life, or property damage,the relief valve must be allowedto dischargewater in quantitiesshouldcircumstances demand.If the dischargepipe is not connectedto a drain or other suitable means, the water flow may causeproperty damage.
The DischargePipe:
•Must nnt be smallerin sizethan the outlet pipe sizeof the valve,or haveanyreducingcouplingsor other restrictions.
•Must not be pluggedor blocked.
•Must be of material listedfor hot water distribution.
•Must be installedso as to allow complete drainageof buth the
Must terminate at an adequatedrain.
[_ Mustnot haveanyvalvebetween the relief valveandtank.
(cont'd)
AWARNING
The
md (2) the water manually dischargedwill not causeany )odily iniuP/ or property damage becausethe water may
)e extremely hot.
If after manually operating the valve, it failsto completely reset and continues to release water, immediately, close the cold water inlet to the water heater, follow the drain-
ing instructions, and replace the
HOTCOLD
HOT
.TEMPERATURE-
PRESSURE
RELIEF VALVE
(Do not €_o or plug)
6" AIR GAP
FLOOR DRAIN
T&P RELIEF |
|
| TEMPERATURE- |
| PRESSURE |
INTO TANK | RELIEF VALVE |
9