INSTALLATION INSTRUCTIONS

CONNECTING TO GAS SUPPLY

The oven is designed to be connected with an approved appliance flexible connection to BS 669. A length of 0.9 to 1.25m is recommended. An adaptor backplate should be fitted in the area shown to allow the appliance to be pushed fully back into the cabinet. The flexible hose should be fitted such that it cannot come into contact with moveable parts of the housing unit (e.g. a drawer) and does not pass through a space where it is likely to become trapped or damaged.

The temperature rise of areas at the rear of the appliance that are likely to come in contact with the flexible hose do not exceed 70oC.

CABINETS LESS THAN 565mm

DEEP

The appliance can be fitted into a cabinet of minimum depth 550mm providing a suitable connection to the gas supply can be made. The wall behind the appliance will need to be chased away behind the appliance gas inlet.

The gas connection can either be made with a flexible hose or 8mm minimum diameter rigid piping, leading below or to the sides of the appliance. Where rigid piping is used, an accessible isolation tap with suitable means of disconnection must be provided to allow for servicing.

200mm

50mm

240mm 410mm

30

Page 30
Image 30
Creda Single Oven manual Connecting to GAS Supply, Deep