INSTALLATION MODE “B”
MODE B is used for vehicles with single wire locking systems that are often called “Data Bus” or
This mode must be programmed using option #16 in the Program Option Section. The Green/White and Red/White wires are NOT used in this mode. Instead, the system “learns” the vehicle’s unlock and lock timing. This mode ONLY requires connection of the Yellow/Black and Blue/Black for arm/disarm sensing. The system will not Arm or Disarm when pressing the factory lock switches. See steps & diagram below for Mode “B”.
Learning the factory Unlock Sequence FIRST!:
1.Turn Ignition on. Press Program switch 9 times.
2.Turn Ignition off, unit chirps twice
3.Press factory alarm remote Lock button
4.Press factory Unlock button when LED starts flashing.
5.Wait
6.Turn Ignition on to exit Program Mode.
Learning the factory Lock Sequence SECOND!:
1.Turn Ignition on. Press Program switch 8 times
2.Turn Ignition off (unit chirps once)
3.Press factory UNLOCK button
4.Press factory Lock button when LED starts flashing.
5.Wait 4 seconds and unit will chirp once.
6.Turn Ignition on to exit Program Mode.
1 K Resistor | Diode |
YELLOW/BLACK
BLUE/BLACK
1 K Resistor | Diode |
(+) PARKING LIGHT WIRE
(+) LOCK MOTOR WIRE
MODE "B" WIRING DIAGRAM (Resistors and Diodes are included)
7