2 Setup
2.1 Installation
CAUTION: Before you begin, make sure your 180MAx is disconnected from the power source, with the power switch in the “off” position and all level controls turned completely down (counterclockwise).
Use a standard
You may also stack
NOTE: When transporting in a rack,
When using an equipment rack, do not mount units directly on top of each other. Allow 2 rack units (3.5 inches) between units for convection cooling. The side walls of the rack should be a minimum of two inches (5.1 cm) away from the amplifier sides, and the back of the rack should be a minimum of four inches (10.2 cm) from the amplifier back panel.
2.2 How to Attach Rack Ears
1.Locate the two rack ears and two
2.See Figure 2.2. Remove the two screws from each side of the chassis near the front.
3.Place a rack ear flush with the right front of the chassis.
4.Insert a screw that you removed into the bottom hole of the rack ear and chassis. Screw it in.
5.Insert a screw that you removed into the center hole of the rack ear and chassis. Screw it in.
6.Insert one of the supplied screws into the top hole of the rack ear and chassis. Screw it in.
7.Repeat steps
Commercial Audio Series Business Music System
Figure 2.2 How to Connect Rack Ears
Figure 2.1 Dimensions
page 8 | Operation Manual |