CE Series Power Amplifiers
3 Operation
3.3 Front Panel Controls and
Indicators
Power Switch
The power switch turns the amplifier on (“I”) or off (“O”).
Note that dangerous voltages may still be present in the amplifier even when the power switch is in the off (“O”) position. Before moving the amplifier or making any wiring or installation changes, it is important to also discon- nect the power cord from the amplifier or power source.
Reset Switch
The
Fault Indicators
Two red LEDs (one for each channel) are located on the front panel. The Fault Indicators are normally OFF, but will blink under five different conditions:
1. When the amplifier is first powered up, until the unit is ready for operation.
2. If the heatsinks reach a temperature above normal working limits.
3. If the transformer thermal protection circuit is activated.
4. If the amplifier output wires develop a
5. If the amplifier output stage stops operating.
The fault status of the amplifier can also be moni- tored remotely by attaching a signalling device to the Fault jack located on the amplifier back panel.
See Section 4.2.2 in this manual for more informa- tion on fault monitoring and suggestions for signal- ling device circuity.
Some fault conditions may cause the output of the amplifier to be muted.
Clip Indicators
These are two red LEDs (one per channel). The Clip Indicator turns on when distortion is audible in the amplifier output.
Signal Indicators
These are two green LEDs (one per channel). The Signal Indicator illuminates when a signal (>
Power Indicator
The green Power indicator lights when your CE- Series amp has been turned on and has power.
Level Controls
Two rotary detented Level controls (one for each channel) are are used to adjust each channel’s out- put.
If you wish, the level control knobs may be pulled from the front panel and the holes plugged with the supplied caps to minimize tampering of control set- tings.
3.4Back Panel Controls and Connectors
Input Sensitivity Switch
This
1.4V input sensitivity or 26 dB gain. Please see Section 2.7 in this manual for details.
Mode Switch
This
Do NOT select
Fault Jack
This is an
Barrier Block Inputs
For each channel, this row of screw terminals pro- vides a balanced input, which is in parallel with the channel’s Combo input connector.
Neutrik Combo Input
One per channel, this combination
Neutrik Speakon® Output
One per channel, this Neutrik Speakon® connector with four terminals connects to loudspeakers.
page 14 | Operation Manual |