MA Series Power Amplifiers

6 Troubleshooting

The table in Figure 6.1 shows the possible states for the ODEP and Signal/IOC indica- tors. It also describes the conditions that may be associated with the different indica- tor states. The Enable indicator will be off with the first indicator state, "There is no power to the amplifier." All other conditions in the table will occur with the Enable indi- cator turned on. It is important to note the possible states of the indicators in the rare event that you experience a problem. This can greatly aid in determining the source of problems. Please contact your local Crown representative or our Technical Support Group for further assistance.

Figure 6.1

Macro-Tech ODEP

and Signal/IOC Indicator Status

Indicator Status

Amplifier Condition

 

 

 

 

 

 

ODEP

 

 

 

OFF

There is no power to the amplifier and all indicators are off, including the Enable light.

 

 

 

Possible reasons: (1) The amplifier’s Enable switch is off. (2) The amplifier is not plugged into the power

 

 

 

 

 

SIGNAL / IOC

 

 

OFF

receptacle. (3) The AC circuit breaker has been tripped. (4) The amplifier’s low-voltage power supply

 

 

fuse has blown.

 

 

 

 

 

 

 

 

 

 

 

ODEP

 

 

 

ON

Normal operation for a channel with NO audio output. Possible reasons: (1) There is no input signal.

 

 

(2) The input signal level is very low. (3) The channel’s level control is turned down.

 

 

 

 

 

SIGNAL / IOC

 

 

OFF

 

 

 

 

 

 

 

 

 

 

ODEP

 

 

 

ON

Normal operation for a channel with audio output. The ODEP indicator will remain at full intensity

 

 

to show that there is reserve thermodynamic energy, and the Signal/IOC indicator will flash with normal

 

 

 

 

 

SIGNAL / IOC

 

 

Normal

intensity to show that the channel has audio output.

 

 

 

 

 

 

 

 

 

ODEP

 

 

 

ON

The channel’s output is exceeding 0.05% distortion. The input signal level is too high and IOC is

 

 

reporting either an input overload or output clipping.

 

 

 

 

 

SIGNAL / IOC

 

 

Bright

OR

 

 

 

 

 

 

 

Channel 2 only: The amplifier is in Parallel-Mono mode. The channel 2 Signal/IOC indicator always

 

 

 

 

 

turns on to full brightness whenever the amplifier's stereo/mono switch is set to Parallel-Mono mode.

 

 

 

 

 

 

ODEP

 

 

 

OFF

The amplifier channel is in standby mode. Possible reasons: (1) A PIP module like an

 

 

IQ-PIP-Lite has turned off the channel’s high-voltage power supply. (2) The amplifier has just been

 

 

 

 

 

SIGNAL / IOC

 

 

Bright

turned on and is still in the four second turn-on delay. (3) The DC / low-frequency protection circuitry has

 

 

been activated. (4) The fault protection circuitry has been activated. (5) The transformer thermal

 

 

 

 

 

 

 

 

 

 

protection circuitry has been activated.

 

 

 

 

 

OR

 

 

 

 

 

A channel’s fuse has blown or breaker has tripped. Transformer overload can cause a channel’s

 

 

 

 

 

internal fuse for its high-voltage supply to blow in a Macro-Tech 602 or 1202, and it can

 

 

 

 

 

cause the channel’s circuit breaker to trip in a Macro-Tech 2402.

OR

ODEP limiting has been activated. Possible reasons: (1) The amplifier’s air filters are blocked and need to be cleaned. (2) There is insufficient cooling because of inadequate air flow or air that is too hot.

(3)The load impedance for the channel is too low because the output is shorted or the amplifier is driving too many loudspeakers for the selected stereo/mono mode. (4) The amplifier channel is continuously being driven to very high output levels.

ODEP

 

 

 

OFF

ODEP limiting is about to begin. Possible reasons: (1) The amplifier’s air filters are blocked and need

 

 

 

to be cleaned. (2) There is insufficient cooling because of inadequate air flow or air that is too hot.

 

 

 

 

 

SIGNAL / IOC

 

 

Normal

(3) The load impedance for the channel is too low because the output is shorted or the amplifier is

 

 

driving too many loudspeakers for the selected stereo/mono mode. (4) The amplifier channel is

 

 

 

 

 

 

 

 

 

 

continuously being driven to very high output levels.

page 18

Operation Manual

Page 18
Image 18
Crown Audio MA-602, MA-1202 operation manual Troubleshooting