SECTION 8. TROUBLE SHOOTING
If your Power Chair will not go, follow this checklist
1.Check that the lights on control box are illuminated.
2.If there are no lights on controller, check that all leads/plugs, which connect to controller, are pushed in properly.
3.Check that the motor cables are properly connected
4.Check all battery wiring is connected.
5.Check that battery box connector is plugged in.
6.Check circuit breaker located on the battery box lid. The circuit breaker will trip when the wheelchair is stalled for a prolonged period or if a major fault has occurred. If circuit breaker continually trips for no apparent reason, cease use and contact nearest Glide Products service agent. Important: Allow 60 seconds before resetting circuit breaker.
7.If you still have problems after reviewing the above checklist, please contact your nearest Glide Rehabilitation Products Agent or Glide Rehabilitation Products direct.