Cuisinart IB-8895A, WCH-1000 performance data sheet, Contaminant Removal Data Important Notice

Models: WCH-1000

1 12
Download 12 pages 27.6 Kb
Page 8
Image 8
performance data sheet

performance data sheet

PERFORMANCE DATA SHEET FOR MODELS WCH-1000 and WCH-1500

CONTAMINANT REMOVAL DATA IMPORTANT NOTICE:

Read this Performance Data Sheet and compare the capabilities of this unit with your actual water treatment needs. It is recommended that, before purchasing a water treatment unit, you have your water supply tested to determine your actual water treatment needs.

Performance testing conducted by WQA. These systems have been tested according to NSF/ ANSI Standard 53 and 42 for reduction of the substances listed below. The concentration of the indicated substances in water entering the system was reduced to a concentration less than or equal to the permissible limit for the water leaving the system, as specified in NSF/ANSI Standard 53 and Standard 42.

Testing was performed under standard laboratory conditions; actual performance may vary.

 

 

 

Removal

Removal

Action Level

Hardness

Temp

Inlet

 

 

 

 

 

 

 

 

 

 

 

 

 

Influent

Filter

 

Max.

 

 

 

 

 

Influent

Percent

Permissible

 

Testing

 

 

Substance

Challenge

Effluent

CaCO3

 

Reduction

Water Avg.

Reduction

Product Water

Compart.

PH

Concentration

Max.

(mg/L)

Requirement

 

(mg/L)

(mg/L)

(mg/L)

(%)

Concentration

 

(°C)

 

 

 

 

 

(mg/L)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

NSF/ANSI Standard 42-Aesthetic Effects

Chlorine Taste and Odor Reduction

2.0

2.0+/-10%

N/A

97.5%

N.A.

N.A.

20

7.53

>50

NSF/ANSI Standard 53-Health Effects

Copper pH 6.5

3.15

3.0+/-10%

.87

85.0%

1.3

16

20

6.42

N/A

 

 

 

 

 

 

 

 

 

 

Copper pH 8.5

3.10

3.0+/-10%

1.0

85.4%

1.3

120

19

8.42

N/A

 

 

 

 

 

 

 

 

 

 

Mercury pH 6.5

.006

0.006+/-10%

.0009

92.8%

0.002

22

19

6.45

N/A

 

 

 

 

 

 

 

 

 

 

Mercury pH 8.5

.006

0.006+/-10%

.001

89.9%

0.002

140

20

8.55

N/A

 

 

 

 

 

 

 

 

 

 

Cadmium pH 6.5

.029

0.03+/-10%

.002

96.6%

0.005

18

20

6.59

N/A

 

 

 

 

 

 

 

 

 

 

Cadmium pH 8.5

.03

0.03+/-10%

.004

92.5%

0.005

120

20

8.44

N/A

 

 

 

 

 

 

 

 

 

 

Benzene

.015

0.015+/-10%

.003

84.1%

0.005

130

20

7.58

N/A

 

 

 

 

 

 

 

 

 

 

Toluene

2.9

3.0+/-10%

.770

89.8%

1

320

20

7.54

N/A

 

 

 

 

 

 

 

 

 

 

Tetrachloroethylene

.014

0.015+/-10%

.003

92.5%

0.005

340

21

7.56

N/A

 

 

 

 

 

 

 

 

 

 

Lead pH 8.5

.149

.15+/-10%

.007

95.4%

.010

98

21

8.5

N/A

 

 

 

 

 

 

 

 

 

 

Lead pH 6.5

.154

.15+/-10%

.004

98.7%

.010

18

19

6.5

N/A

 

 

 

 

 

 

 

 

 

 



Page 8
Image 8
Cuisinart IB-8895A, WCH-1000 manual performance data sheet, Contaminant Removal Data Important Notice