Cuisinart WCH-950 manual Performance Data Sheet, Contaminant Removal Data Important Notice

Models: WCH-950

1 13
Download 13 pages 28.84 Kb
Page 9
Image 9
Manual background

PERFORMANCE DATA SHEET

PERFORMANCE DATA SHEET FOR MODELS WCH-850 AND WCH-950

CONTAMINANT REMOVAL DATA IMPORTANT NOTICE:

Read this Performance Data Sheet and compare the capabilities of this unit with your actual water treatment needs. It is recommended that, before purchasing a water treatment unit, you have your water supply tested to determine your actual water treatment needs.

Performance testing conducted by WQA. These systems have been tested according to NSF Standard 53 for reduction of the substances listed below. The concentration of the indicated substances in water entering the system was reduced to a concentration less than or equal to the permissible limit for the water leaving the system, as specified in NSF Standard 53.

Testing was performed under standard laboratory conditions; actual performance may vary.

 

 

 

 

Removal

Action Level

Hardness

Temp

Inlet

 

 

 

 

 

 

 

 

 

 

 

 

 

Required

Filter

 

Max.

 

 

 

 

 

Influent

Influent

Percent

Permissible

 

Testing

 

 

Substance

Effluent

CaCO3

 

Reduction

Water Avg.

Challenge

Reduction

Product Water

Compart.

PH

Max.

(ppm)

Requirement

 

(ug/L)

Concentration

(%)

Concentration

(°C)

 

 

(ug/L)

 

 

 

 

 

(mg/L)

 

(ug/L)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

NSF/ANSI Standard 53-Health Effects

Lead

149

150+/-10%

7.3

95.4%

10

98

21

8.5

N/A

Lead

154

150+/-10%

4.0

98.7%

10

18

19

6.5

N/A

9

Page 9