28Installing the VoIP Loudspeaker Amplifier Restore the Factory Default Settings
2.6 Restore the Factory Default Settings
When troubleshooting configuration problems, it is sometimes convenient to restore the device to a known state.
Each loudspeaker amplifier is delivered with factory set default values for the parameters indicated in Table
When you use the RTFM switch, the factory default settings are restored for only the parameters indicated in Table
| Table |
|
|
Parameter | Factory Default Setting |
|
|
IP Addressing | static |
|
|
IP Address | 192.168.3.10 |
|
|
Web Access Username | admin |
|
|
Web Access Password | admin |
|
|
Subnet Mask | 255.255.255.0 |
|
|
Default Gateway | 192.168.3.1 |
|
|
To restore these parameters to the factory default settings:
1.Press and hold the RTFM switch for 20 seconds.
2.The loudspeaker amplifier will beep after one second. Continue to hold the switch until the loudspeaker amplifier beeps again after 20 seconds.
3.Release the switch. The following occurs:
•A voice message announces that the factory default settings are being restored.
•Once the settings are restored, a voice message announces the restored default IP address:
192.168.3.10
•A voice message announces that the loudspeaker amplifier is rebooting.
•The loudspeaker amplifier reboots.
CyberData Corporation | 930106D | VoIP Loudspeaker Amplifier Operations Guide |