DC Fuse Replacement (For Cigar Plug Cable)

The CPS480PAU inverter contains a fuse inside in the cigar plug (see Figure 1) to protect the unit against overloading. If the inverter draws more than 150 watts, the internal fuse may open to protect the inverter, vehicle battery, and the connected equipment. To replace the fuse, please follow the instructions below:

1.Unplug the inverter from the power source.

2.Remove the contact retainer from the 12V DC adapter.

3.Replace the 15 amp fuse.

4.Reassemble the fuse, contact pin, and contact screw carefully.

5.Ensure all pieces shown in Figure 1 are installed in the correct sequence.

 

Spring

12V DC Adapter

Decorative Ring

 

 

Contact Pin

15 ampFuse

Contact Retainer

Figure 1. Fuse Replacement

Specifications

Model

CPS240PAU

CPS480PAU

Input Voltage

11 to 15 volts

Output Peak Power

240 Watts

480 Watts

 

Output Continuous Power

200 Watts

400 Watts

Output Voltage

 

120 Volts

 

Output USB Voltage

 

5 Volts

 

Output Frequency

 

60 Hz

 

Output Waveform

Simulated Sine Wave

 

Input Fuse (Internal)

25Amp

25Amp x2

 

Input Fuse (Cigar plug)

15Amp (CPS480PAU only)

 

Protection Features

Overload, Overvoltage,

 

 

Overheating, Short-circuit

Troubleshooting

Problem

Possible Cause

Suggested Solutions

 

 

 

 

No AC output -

1.DC input is below 11

1.Check your battery volts

Red LED lit.

Vdc / Over 15Vdc

and recharge or replace the

 

2.Short circuit.

battery.

 

3. Overload

2. Disconnect the load.

 

4. Inverter hot.

3. Reduce the load.

 

 

4. Disconnect the load and

 

 

operate the inverter for a

 

 

few minutes.

No AC output -

1.Bad connection or

1.Tighten all DC connections.

Green LED not

wiring

 

 

lit.

2.Fuse is blown

2.Check fuse and replace or

 

 

Call Service

Motorized power

Excessive startup load.

Disconnect the load until the

tool will not

If the start up load

inverter operates normally

operate

exceeds the inverters

and connect the load again.

 

peak load capability it

 

 

 

will not work.

 

 

Limited Warranty

Note Page

CyberPower warrants this CPS240PAU / CPS480PAU (the "Inverter") to be free from material and manufacturing defects for two years. If a defect results in product failure during its normal use, CyberPower’s sole responsibility is to repair or replace (at its sole option) the Inverter.

The foregoing Limited Warranty is the consumer’s sole and exclusive remedy and excludes any incidental or consequential damages. Some States do not allow the exclusion or limitation of incidental and consequential damages, so certain of the above limitations or exclusions may not apply to you (the Consumer). This limited warranty gives the Consumer specific legal rights and the Consumer may have other rights, which vary from State to State.

To make a Limited Warranty claim:

1.Pack and ship the Inverter to CyberPower at 4241 12th Avenue East, Suite 400, Shakopee, MN 55379.

2.Clearly indicate on the outside of the packaging that this is a “WARRANTY RETURN”

3.Clearly include your name and address (a) on the outside packaging and (b) on a sheet of paper enclosed in the box with the Inverter that is being returned.

4.You MUST prepay all shipping costs and you are responsible for packaging and shipment.

CAUTION: Any changes or modifications not expressly approved by the guarantee of this device could void the user’s authority to operate the equipment.

Product Registration

Thank you for purchasing a CyberPower product. Prompt product registration entitles coverage under the Limited Warranty and also allows the opportunity to be notified of product enhancements, upgrades, and other announcements.

Registration is quick and easy at www.cpsww.com/register

Technical Support

Feel free to contact our Tech Support department with installation, troubleshooting, or general product questions.

CyberPower Technical Support

Phone: 1-877-297-6937

Email: tech@cpsww.com

Web: www.CPSww.com

Address: 4241 12th Ave. E., STE 400, Shakopee, MN 55379

Hours of Operation: Monday – Friday, 7:00am – 6:00pm (CST)

Legal notices (FCC Part 15)

This equipment has been tested and found to comply with the limits for a Class B Digital Device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: (1) Reorient or relocate the receiving antenna. (2) Increase the separation between the equipment and receiver. (3) Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. (4) Consult the dealer or an experienced radio/TV technician for help. Any special accessories needed for compliance must be specified in the instruction.

CAUTION: A shielded-type power cord is required in order to meet FCC emission limits and also to prevent interference to the nearby radio and television reception. It is essential that only the supplied power cord be used. Use only shielded cables to connect I/O devices to this equipment.

CyberPower Systems (USA), Inc.

4241 12th Avenue East, Suite 400, Shakopee, MN 55379

TEL: (952) 403-9500 Toll-Free: (877) 297-6937

FAX: (952) 403-0009 E-mail: sales@cpsww.com

CPSww.com

C2014 CyberPower Systems, Inc.

All rights reserved. Reproduction in whole or in part without permission is prohibited.

K01-0000377-01

Page 2
Image 2
CyberPower CPS480PAU, CPS240PAU warranty DC Fuse Replacement For Cigar Plug Cable, Specifications, Troubleshooting