Bunn TB3Q TROUBLESHOOTING cont PROBLEM, Probable Cause, Remedy, CAUTION - Do not eliminate or by

Models: TB3Q TB3Q-LP

1 27
Download 27 pages 51.73 Kb
Page 11
Image 11

TROUBLESHOOTING (cont.)

PROBLEM

Brew cycle will not start (cont.)

PROBABLE CAUSE

6.Brew Timer

7.Brew Solenoid Valve

REMEDY

Refer to Service - Brew Timer for testing procedures. See page 17

Refer to Service - Brew Solenoid Valve for testing procedures. See page 16

Water is not hot

1. Limit Thermostat

Refer to Service - Limit Thermostat

CAUTION - Do not eliminate or by-

for testing procedures. See page

pass limit thermostat or thermal

20.

cut-off. Use only BOM replacement

 

part #29329.0001

 

2. Control Thermostat

Refer to Service - Control Thermo-

 

stat for testing procedures. See

 

page 19

Dilution cycle will not start

Inconsistent beverage level in dispenser

3.Tank Heater

1.ON/OFF

2.Start Switch

1.Syphon System

2. Lime Build-up

CAUTION - Tank and tank compo- nents should be delimed regularly depending on local water condi- tions. Excessive mineral build-up on stainless steel surfaces can ini- tiate corrosive reactions resulting in serious leaks.

Refer to Service - Tank Heater for testing procedures. See page 25

Refer to Service - ON/OFF Switch for testing. See page 21

Refer to Service - Start Switch for testing procedures. See page 22.

The brewer must be level or slightly lower in front to syphon properly

Inspect the tank assembly for ex- cessive lime deposits. Delime as required.

3. Water Pressure

The water pressure to the brewer

 

must be at least 20 psi (138 kPa).

Page 11

37236 050305

 

Page 11
Image 11
Bunn TB3Q-LP service manual TROUBLESHOOTING cont PROBLEM, Probable Cause, Remedy, CAUTION - Do not eliminate or by