TROUBLESHOOTING (cont.)
PROBLEM
Brew cycle will not start (cont.)
PROBABLE CAUSE
6.Brew Timer
7.Brew Solenoid Valve
REMEDY
Refer to Service - Brew Timer for testing procedures. See page 17
Refer to Service - Brew Solenoid Valve for testing procedures. See page 16
Water is not hot
1. Limit Thermostat | Refer to Service - Limit Thermostat |
CAUTION - Do not eliminate or by- | for testing procedures. See page |
pass limit thermostat or thermal | 20. |
|
|
part #29329.0001 |
|
2. Control Thermostat | Refer to Service - Control Thermo- |
| stat for testing procedures. See |
| page 19 |
Dilution cycle will not start
Inconsistent beverage level in dispenser
3.Tank Heater
1.ON/OFF
2.Start Switch
1.Syphon System
2. Lime
CAUTION - Tank and tank compo- nents should be delimed regularly depending on local water condi- tions. Excessive mineral
Refer to Service - Tank Heater for testing procedures. See page 25
Refer to Service - ON/OFF Switch for testing. See page 21
Refer to Service - Start Switch for testing procedures. See page 22.
The brewer must be level or slightly lower in front to syphon properly
Inspect the tank assembly for ex- cessive lime deposits. Delime as required.
3. Water Pressure | The water pressure to the brewer |
| must be at least 20 psi (138 kPa). |
Page 11 | 37236 050305 |
|