TROUBLESHOOTING (cont.)
PROBLEM
Consistently high or low beverage level in the dispenser
Spitting or excessive steaming
PROBABLE CAUSE
1. Strainer/Flow Control (.750GPM)
1. Lime
CAUTION - Tank and tank compo- nents should be delimed regularly depending on local water condi- tions. Excessive mineral
REMEDY
(A)Direction of flow arrow must be pointing upwards in the brewer.
(B)Remove the strainer/flow con- trol and check for obstructions. Clear or replace.
Inspect tank assembly for excessive lime deposits. Delime as required.
| 2. | Control Thermostat | Refer to Service - Control Thermo- |
|
|
| stat for testing procedures. See |
|
|
| page 19 |
1. Funnel Tip | The brew funnel should be cleaned | ||
|
|
| thoroughly before each brew cycle |
|
|
| to lessen the chance of tea leaf par- |
|
|
| ticles clogging the |
Sweetener is not working | 1. | Sweetener box is empty | Check the Sweetener box to make |
|
|
| sure it is not out of product. |
| 2. Flow Adjustment screw is closed | Check the Flow Adjustment screw | |
|
|
| to make sure the valve has not |
|
|
| closed. |
| 3. | Solenoid is defective | Refer to Service |
|
|
| noid Valve for testing procedures. |
|
|
| See page 24. |
| 4. | The Pump is defective | Check the manufacturers warranty |
|
|
| for additional information on test- |
|
|
| ing and replacement of a defective |
|
|
| pump. |
Page 12 | 37236 050305 |
|