TROUBLESHOOTING (cont.)
PROBLEM
Dripping from sprayhead
PROBABLE CAUSE
1.Syphon System
2.Lime
CAUTION - Tank and tank compo- nents should be delimed regularly depending on local water condi- tions. Excessive mineral
REMEDY
The brewer must be level or slightly lower in front to syphon properly.
Inspect the tank assembly for ex- cessive lime deposits. Delime as required.
3. Brew Solenoid Valve | Refer to Service - Brew Solenoid |
| Valve for testing procedures. See |
| page 16 |
Water flows into tank continuously 1. Brew Timer (ON/OFF Switch "ON")
(UNSWEET/OFF/SWEET Switch in "UNSWEET" or "SWEET" position)
Refer to Service - Brew Timer for testing procedures. See page 17
Water flows into tank continuously (ON/OFF Switch "OFF") (UNSWEET/OFF/SWEET Switch in "OFF" position.
Beverage overflows dispenser
1. | Brew Solenoid Valve | Refer to Service - Brew Solenoid |
|
| Valve for testing procedures. See |
|
| page 16 0r 24 |
1. | Dispenser | The dispenser must be completely |
|
| empty before starting a brew cycle. |
2. | Brew Timer | Refer to Service - Brew Timer for |
|
| testing procedures. See page 17 |
3. | Brew Solenoid Valve | Remove the Brew Solenoid Valve |
|
| and clean any obstruction. Rebuild |
|
| or replace the valve if necessary. |
|
| See page 16 |
Weak beverage | 1. | Filter Type | BUNN® paper filters must be used |
|
|
| for proper extraction. |
| 2. | Tea | A sufficient quantity of fresh, loose |
|
|
| tea leaves should be used for proper |
|
|
| extraction. |
| 3. | Sprayhead | A clean stainless steel sprayhead |
|
|
| must be used for proper extrac- |
|
|
| tion. |
Page 13 | 37236 050305 |
|