Guaranteed Uninterruptible Power System

As the battery discharges, the unit will beep more rapidly, indicating that the battery is nearing discharge. Once the test is complete, plug the UPS back in to the AC outlet and start your computer. Please allow 4 hours for the UPS to recharge before attempting another self-test.

DEFINITIONS FOR ILLUMINATED LED INDICATORS

Power

Wiring

AVR

Using

Check

Circuit

Alarm

Condition

Fault

 

Batter

Battery

Breaker

 

 

On

 

 

 

 

 

y

 

 

 

 

On

Off

Off

Off

Off

Set

Off

Normal

On

Off

Flash

Off

Off

Set

Off

AVR- AVR is maintaining a consistent 120v level (±5%)

 

 

 

 

 

 

 

during a power sag.

ON

Off

On

Off

Off

Set

Off

AVR- AVR is maintaining a consistent 120v (±5%)

 

 

 

 

 

 

 

during a power surge

Off

On/Off

Off

On

Off

Set

Two Beeps

Utility Failure- The UPS is providing battery power to

 

 

 

 

 

 

 

the Battery-Power Supplied outlets.

Off

On/Off

Off

On

Off

Set

Rapid Beeps

Utility Failure- The UPS is providing battery power.

 

 

 

 

 

 

 

The rapid beeps indicate the battery will run out of

 

 

 

 

 

 

 

charge within a few minutes.

Off

Off

Off

On

Off

Up

Two beeps or rapid

Overload- Occurs in the Full-time Surge Protection

 

 

 

 

 

 

beeps

Outlets. Turn the UPS off and unplug at least one

 

 

 

 

 

 

 

piece of equipment from the UPS. Wait 5 seconds,

 

 

 

 

 

 

 

reset the circuit breaker and turn the UPS on.

On/Off

On/Off

On/Flash/Off

On/Off

Off

Set

Long Beep

Overload- Occurs in the Battery-power Supplied

 

 

 

 

 

 

 

Outlets. Turn the UPS off and unplug at least one piece

 

 

 

 

 

 

 

of equipment from the UPS. Wait 5 seconds, reset the

 

 

 

 

 

 

 

circuit breaker and turn the UPS on.

Off

Off

Off

On

Off

Up

Long Beep

Overload- Occurs in the Battery-power Supplied

 

 

 

 

 

 

 

Outlets. Turn the UPS off and unplug at least one piece

 

 

 

 

 

 

 

of equipment from the UPS. Wait 5 seconds, reset the

 

 

 

 

 

 

 

circuit breaker and turn the UPS on.

On

On/Off

On/Flash/Off

Off

On

Set

None

Weak Battery- Recharge the battery for at least 8

 

 

 

 

 

 

 

hours. If Check Battery is illuminated contact

 

 

 

 

 

 

 

CyberPower Systems for battery replacement

 

 

 

 

 

 

 

information.

Off

Off

Off

Off

Off

Set

Off

Surge Protection Malfunction- Lightning induced

 

 

 

 

 

 

 

power line surge has damaged the surge-protect

 

 

 

 

 

 

 

function. Please contact CyberPower Systems

On/Off

On/Off

On/Flash/Off

Flash

Flash

Set/Up

Off

Scheduled Turn-on-If the two battery indicators are

 

 

 

 

 

 

 

flashing in rotation, the UPS is waiting to turn on as

 

 

 

 

 

 

 

configured in the schedule.

On/Off

On/Off

On/Flash/Off

Flash

Flash

Set/Up

Three Beeps

Cold Start Disabled- If the two battery indicators are

 

 

 

 

 

 

 

flashing at the same time, the cold-start has been

 

 

 

 

 

 

 

disabled. The UPS will not start in the absence of AC

 

 

 

 

 

 

 

power.

On/Off

On

On/Flash/Off

On/Off

On/Off

Set/Up

None

Electrical Wiring Fault- This indicates a wiring a

 

 

 

 

 

 

 

problem such as a bad ground, missed ground or

 

 

 

 

 

 

 

reversed wiring within the AC outlet. User is advised

 

 

 

 

 

 

 

to disconnect all electrical equipment from the outlet and

 

 

 

 

 

 

 

have the outlet checked by an electrician.