Dacor 100500 manual Electrical Requirements, Water Supply Requirements, Cold water supply

Models: 100500

1 20
Download 20 pages 24.16 Kb
Page 10
Image 10

Installation Specifications

Rough-In Dimensions

The solid sofit or ceiling should be within 1” (25mm) above the refrigerator. If the solid sofit is higher than 1” (25mm) or one is not available, then the refrigerator must be braced to prevent tipping during use. If the anti-tip blocking is need.

(see “Anti-Tip Blocking” on page 9)

NOTE: A clearance of 1/2” (13mm) must be maintained above the top grill in order for the top grill to be opened.

A grounded 3 prong non-GFCI electrical outlet should be placed 2” (51mm) from the right side cabinets or end panel. See “Electrical Requirements” for additional information.

The plumbing for the water line can come through the floor or the back wall. See “Water Supply Requirements” for more information.

“A”

 

 

2”

 

 

Electrical

 

7”

 

 

 

4”

83 3/4”

 

 

 

75 1/2”

 

6”

 

 

Water Supply

3”

24”

Electrical Requirements

WARNING

Electrical shock Hazard – Plug into a grounded 3- prong non-GFCI outlet. Do not remove ground prong. Do not use an adapter. Do not us an extension cord. Failure to do so can result in death, fire, or electrical shock.

A 115VAC, 60 Hz, 15 Amp circuit breaker and electrical supply are required. A separate dedicated non-GFCI circuit, servicing only this appliance, is required.

Your Dacor® Built-In refrigerator is equipped with a 40” (1016mm) 3-prong grounded power cord, which must be plugged into a

3-prong grounding-type non-GFCI wall receptacle. Follow the National Electrical Code and local codes and ordinances when installing the receptacle. See “Rough-In Dimensions” for location of the electrical supply.

IMPORTANT: A ground fault circuit interrupter (GFCI) is not recommended and may cause interruption of operation.

Water Supply Requirements

All installations must meet local plumbing code requirements.

Connect to 1/4” (6mm) copper line to the house cold fresh water supply.

Use a shut off valve between the refrigerator and supply. The shut off valve should be a drilled saddle valve.

Do not use a self-tapping valve which reduces water flow and clogs more easily.

Route the water line within 3-1/2” (89mm) of the rear wall and no higher than 3” (76mm) from the floor.

Allow a minimum of 24” (610mm) dimeter service loop of copper tubing outside the wall or floor for easy connection to the water supply.

Cold water supply

Connect the ice maker to a cold water line with water pressure between 30 and 120 PSI. If you have any questions about your water pressure, call your utility company.

IMPORTANT:

In homes with a Reverse Osmosis water treatment system, remove the water inlet connector from the “yellow” valve and attached to the “blue” valve. Make sure the water filter bypass plug is in place.

Model

Rough-In Width “A”

42-Inch

41 1/2”” (1054mm)

48-Inch

47 1/2”” (1207mm)



Page 10
Image 10
Dacor 100500 manual Electrical Requirements, Water Supply Requirements, Cold water supply, Model Rough-In Width a