Preparing for Installation
Preparing the Location
Cutout tolerances: +1/16” (+1.6 mm),
warning
Follow all cabinet dimensions shown to insure safe operation. All minimum product dimensions must be met or exceeded (see page 3). Dimensions shown provide the required clearances.
• | The cabinet must enclose the dishwasher on the |
|
|
|
|
|
|
|
|
|
|
|
|
|
| 2” (5.1 cm) |
|
| * |
|
|
| ||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||||||
| top, back and both sides. |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| 34 1/2” |
|
|
| ||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| (87.6 cm) |
|
|
| |||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||
• | Carefully check the location where the |
|
|
|
|
|
|
|
|
|
|
|
|
|
| 4” (10.2 cm) |
|
| to |
|
|
| ||
| dishwasher is to be installed. Put it in a location |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| 36 1/2” |
|
|
| |||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||||
| with convenient access, close to the kitchen |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| (92.7 cm) |
|
|
| ||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||||
| sink for easy water supply and drain connection. |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| The power supply shall meet the Electrical |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| Specifications on page 4. Also, the electrical |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
| outlet or junction box shall be installed close by |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
| in a cabinet adjacent to the location selected so |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| 24” |
|
|
|
|
| ||
| that the power cable can be disconnected without |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||||
|
|
|
|
|
|
|
|
|
| 5 3/8” |
| (61.0 cm) |
|
| ||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
| ||||||||||||
| removing the appliance from the cutout. |
|
|
|
|
|
|
|
|
|
|
|
| |||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||||
• | The electrical wiring, water supply and drain |
|
|
|
|
|
|
| (13.6 cm) |
|
|
|
|
|
|
|
| |||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||
| lines must enter through the area indicated by |
|
|
|
|
|
|
|
|
|
|
|
|
| 24” (61.0 cm) |
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||
| the shading on the illustration at right. Preferably, |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| Dishwasher Cutout - Front View |
|
| |||||||||||||||
| they should come through the right side of the |
|
|
|
|
|
|
|
|
cabinet. | * If the height of the existing cutout is too low: |
|
•The access hole(s) in the cabinet for the power cord and water line shall be no bigger than
(3.8 cm) in diameter. The access hole for the drain hose shall be no bigger than 2˝ (5.0 cm) in diameter. The access holes for all three must be round and smooth. If the partition is metal, it needs to be covered with an edge protector. Call Dacor for the part number of an approved edge protector.
•The opening through the partition between the drain connection and the dishwasher cutout must be higher than the disposer or waste tee connection (see page 6) and lower than 35” (88.9 cm).
•Plan the installation so that the appliance can be removed easily if service is required.
mm)by not installing the plastic feet on the unit as shown on page 9. Extra care must be taken if the feet are not installed. Dacor is not responsible for floor damage during installation.
by removing the trim pieces that surround the wash compartment opening. NOTE: Doing so will create a gap of 1/4” (6.0 mm) on the right and left side of the door.
•If the dishwasher is installed in a corner, allow a minimum clearance of 2” (5.1 cm) from the side wall so the door can open. See diagram, right.
•The floor must be solid, level and all cutout surfaces must be at right angles. In the interest of safety, the surrounding cabinet must have sufficient material for attachment of the
2”(5(5.1 cm).1 cm)Min.
clearance
Minimum Door Clearance
5