Installation Instructions
3.Connect the hood wiring to an electrical junction box on a dedicated circuit. See page 4 for specifications. Connect it according to one of the wiring diagrams below.
To house circuit breaker
panel or fuse box
Wire nut,
3 places WHITE WHITE
GREEN BLACK
GREEN BLACK
Junction
box
To range | UL/CSA approved |
hood | NEMA strain relief |
Separate No. 10 (minimum)
copper ground wire
To house circuit breaker
panel or fuse box
Fasten clamp tightly on pipe
Wire nut,
3 places WHITE WHITE
GREEN BLACK
GREEN BLACK
Junction
box
To range | UL/CSA approved |
hood | NEMA strain relief |
warning
•Do not ground the circuit to a gas line or hot water pipe.
•Water lines that are insulated must be jumped to assure continuity to ground. See below.
Meter
No. 4 copper
wire
Clamps
Bare metal
Insulated Pipe Jumper(if necessary)9