Installation Instructions

Electrical Connection

warning

If the electrical service provided does not meet the Electrical Specifications (see page 4), do not proceed with the installation. Call a licensed electrician to correctly install the required wiring.

Failure to disconnect power prior to installation may result in an electrical shock or fire hazard.

Do not turn on power to the appliance until the oven is properly grounded according to these instructions.

The installer must connect the ground terminal (or lead) on the appliance to a grounded, metallic, perma- nent wiring system or grounding conductor. Failure to do so may result in an electric shock hazard.

Do not use an extension cord with this appliance. Such use may result in fire, electric shock or personal injury.

Do not install a fuse in the neutral or ground circuit. A fuse in the neutral or ground circuit may result in an electric shock hazard.

The appliance must be connected to the power supply with copper wire only. The use of aluminum wire may result in unsatisfactory conditions.

IMPORTANT

Provide slack in the conduit to allow the oven to slide forward for servicing.

note

The electrical connection leads from the supplied appliance conduit may be a smaller gage than the standard household wiring of the dedicated supply circuit. They are suitable for connection to household wiring under the jurisdiction of the National Electric Code, and/or the local inspection authority.

1.Before proceeding, turn off power to the circuit to which the oven will be connected at the circuit breaker or fuse box.

2.Position the oven directly in front of the cabinet cut out.

3.Feed the appliance conduit into the electrical junction box and attach it using a UL approved strain relief.

4.Depending upon local codes, utilize one of three meth- ods to connect the appliance to the electrical power:

Connect to a four wire electrical system

Connect to a three wire electrical system, where local codes permit

Connect to a three wire electrical system with external ground, according to local codes.

See pages 9 to 11 for detailed directions.

Connecting to a Four Wire Electrical System

1.Separate the wires coming out of the appliance conduit.

2.Connect the white wire from the appliance conduit to the white (neutral) supply wire in the junction box.

3.Connect the black wire from the appliance conduit to the black (L1) supply wire in the junction box.

4.Connect the red wire from the appliance conduit to the red (L2) supply wire in the junction box.

5.Connect the green wire from the appliance conduit to the green (ground) wire in the junction box.

 

Incoming power

Junction box

Wire nut,

 

4 places

RED

WHITE

RED

WHITE

 

GREEN

BLACK

GREEN

BLACK

 

Conduit to oven

Four Wire Connection

continued...

9