Installation Instructions
Electrical Connection (cont.)
Appliance Wire Connections - Where Local Code Permits
WARNING
Do not connect the green appliance wire to the neutral (white) supply wire unless local building codes permit.
1.Remove the range electrical access cover from the back of the range.
2.If using a 4 wire connection, loosen the grounding screw and remove the neutral to ground jumper link.
3.Remove the conduit bracket from the bottom of the range electrical box.
Remove jumper on 4 Wire installations
Remove conduit bracket before strain relief installation
4.Disassemble and remove the strain relief from the appliance cord (not included). Insert the tabs on the two parts of
the strain relief into the hole on the bottom of the box and reassemble it so that the tabs are below the box and the strain relief itself is inside the box.
Strain Relief
5.Slide the end of the appliance cord into the strain relief from the bottom of the box
6.Connect the white (neutral) wire to the neutral terminal in the box.
7.Connect the L1 wire to the L1 power supply terminal in the box.
8.Connect the L2 wire to the L2 power supply terminal in the box.
9.If using a 4 wire connection, connect the ground wire to the grounding screw inside the box.
10.Tighten the strain relief so that the appliance cord is held snuggly in place.
11.Replace the range electrical access cover.
L1 Terminal
Neutral Terminal
L2 Terminal
Jumper Link
L1 Wire
White Wire
L2 Wire
Strain Relief
3 Wire Appliance Cord
Connection -
Where Local Code Permits
L1
Neutral
|
| L2 | |
Bottom of range | Reassemble with tabs | ||
electrical box | below and clamp above |