Installation Instructions

Electrical Connection

WARNING

Wire the range only in compliance with local ordinances.

Improper connection of the electrical wiring can cause an electric shock hazard and damage the appliance. Dacor is not responsible for damages resulting from improper installation.

Connect the ground terminal (or lead) on the appliance to a grounded, metallic, permanent wiring system or grounding conductor.

Do not use an extension cord with this appliance. Such use may result in fire, electric shock or other personal injury.

Do not install a fuse in the neutral or ground circuit. A fuse in the neutral or ground circuit may result in an electric shock hazard.

NOTE: Ranges equipped for use in Canada come from the factory pre-wired. If installing a pre-wired range, skip to the Gas Supply Connection section on page 15.

IMPORTANT:

Do not disconnect any of the wires inside the range electrical box unless instructed to do so.

Make sure that the conduit or appliance cord is long enough to allow the range to be pulled out for service without disconnecting it from power.

Put slack in electrical wiring and gas line

For safety, replace the electrical access cover after connecting the wiring.

Gas Regulator

Access Cover

Electrical Access Cover

Refer to the range rating label (see page 3) for power requirements.

There are four possible ways to wire the range:

4 Wire Conduit

3 Wire Conduit (where local codes permit)

4 Wire Appliance Cord (where local codes permit)

3 Wire Appliance Cord (where local codes permit)

The sections below and on the following pages give directions for connecting each type of wiring harness.

WARNING

Do not connect the green appliance wire to the neutral (white) supply wire unless local building codes permit.

Connecting Conduit to the Range

NOTE: For connection of an appliance cord, see page 14.

1.Remove the range electrical access cover from the back of the range.

2.If using a 4 Wire connection, loosen the grounding screw and remove the neutral to ground jumper link.

3.Remove the nut from the conduit strain relief (not included).

4.Slide the wires and the end of the strain relief into the hole on the bottom of the range electrical box.

5.Before connecting the wires, slide the strain relief nut over the wires and thread it onto the conduit strain relief inside the box. Tighten into place.

6.Connect the white wire to the neutral terminal in the box.

7.Connect the black wire to the L1 power supply terminal.

8.Connect the red wire to the L2 power supply terminal.

9.If using a 4 Wire connection, connect the green wire to the grounding screw inside the box.

10.Replace the range electrical access cover.

Back of Range

Gas and Electrical Access Covers