Dacor AESP03 dimensions ERD60, 60” Wide, Planning, Epicure Range, Guide, Corporate Phone, Revised

Models: ERD60LP ERD60 AESP03 ERD30

1 2
Download 2 pages 2.38 Kb
Page 1
Image 1
ERD60

ERD60

Revised

60” Wide,

 

PLANNING

Epicure® Range

1/2

GUIDE

06/25/08

1 9/16" Revised (40mm) 60” Wide,

28 1/2" (724mm) 27" (686mm)

26" (660mm)

24 3/8" (619mm)

When Backguard and PLANNING Side Panels are

removed, the overall depth decreases by 1" (25mm)

Handle

Front Edge of Bullnose

Face of Control Panel/Oven Door

Rear of Control Panel/Oven Door

6” (152mm) Backguard

37”

(940mm)

to

353/4"

(908mm)

Epicure® Range warning

Observe all governing codes and ordinances during planning and installation. Contact your local building department for further information.

This appliance must be installed in accordance with the accompanying installation instructions.

Finished Side Panel

60" (1524mm)

6" (152mm) Backguard GUIDE06/25/08

Accessory 3” (76mm) Side Panels

(Dacor Model No. AESP03)

erd/eGR30, erd60 overall dimensions

side view

 

 

Power Cords

 

Factory installed 3/4” regulators

 

 

 

 

 

(1/2” supply ok)

 

 

 

 

rear view

 

 

 

 

 

 

 

 

 

 

Total

 

 

 

 

Dacor®Dedicated Circuit*Connected

 

Gas

ManifoldMin. Gas Supply
Model No.RequiredLoad

 

TypePressure

Pressure

ERD60

240 Vac, 4-wire, 60 Hz,

4.1 kW

 

Natural

5” Water Column

6” Water Column

ERD60LP

 

Liquid

 

 

30 Amp (Breaker) X2

(21Amp) X2

 

10” Water Column

11” Water Column

 

 

Propane

 

 

 

 

 

 

*Two separate dedicated circuits are required, one for left and one for the right side of the range.

Electrical AND GAS Supply Requirements

60" (1524mm) NOTES:

1.Utilities may be located in the lower left corner of the adjacent right cabinet. (Recommended)

2.Contact your local building department to verify compliance with local code interpretation.

3.Two electrical circuits and gas supplies required.

Web: http://www.Dacor.com

Specifications are subject to change without notice.

5.7

Corporate Phone: 800-793-0093
See installation instructions for additional details.
Page 1
Image 1
Dacor AESP03 dimensions ERD60, 60” Wide, Planning, Epicure Range, Guide, Two electrical circuits and gas supplies required