Dacor EF36, IF36 Performance Data, General Use Conditions, Specifications

Models: EF36 IF36

1 24
Download 24 pages 37.47 Kb
Page 11
Image 11
PERFORMANCE DATA

PERFORMANCE DATA

Standard No. 42: Aesthetic Effects

 

USEPA

Influent

Influent

Effluent

% Reduction

Min. Required

 

 

 

 

 

Parameter

MCL

Challenge Concentration

Average

Average

Maximum

Average

Minimum

Reduction

 

 

 

 

 

 

 

 

 

Cholorine

2.0 mg/L ± 10%

1.88 mg/L

<0.05136364 mg/L

0.06 mg/L

>97.26

96.84

50%

 

 

 

 

 

 

 

 

 

Taste and Odor

 

 

 

 

 

 

 

 

 

Particulate**

at least 10,000 particles/ml

5,700,000 #/ml

30,583 #/ml

69,000 #/ml

99.52

98.94

85%

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Standard No. 53: Health Effects

 

 

 

 

 

 

 

 

 

 

 

 

USEPA

Influent

Influent

Effluent

% Reduction

Min. Required

 

 

 

 

 

Parameter

MCL

Challenge Concentration

Average

Average

Maximum

Average

Minimum

Reduction

 

 

 

 

 

 

 

 

 

Turbidity

1 NTU**

11 ± 1 NTU***

10.7 NTU

0.31 NTU

.049 NTU

97.09

95.20

0.5 NTU

 

 

 

 

 

 

 

 

 

 

99.5%

 

 

 

 

 

 

 

Cysts

Reduction

Minimum 50,000/L

166,500 #/L

<1 #/L

<1 #/L

>99.99

>99.99

>99.99%

 

 

 

 

 

 

 

 

 

 

99%

107 108 fibers/L; fibers > micrometers

 

 

 

 

 

 

Asbestos

Reduction

in length

155 MF/L

<1 MF/L

<1 MF/L

>99.99

>99.99

99%

 

 

 

 

 

 

 

 

 

Lead at pH 6.5

0.015 mg/L

0.15 mg/L +10%

0.153 mg/L

<.001 mg/L

<.001 mg/L

>99.35

>99.29

0.10 mg/L

 

 

 

 

 

 

 

 

 

Lead at pH 8.5

0.015 mg/L

0.15 mg/L +10%

0.150 mg/L

<.001 mg/L

<.001 mg/L

>99.33

>99.29

0.10 mg/L

 

 

 

 

 

 

 

 

 

Mercury at pH 6.5

0.002 mg/L

.006 mg/L ± 10%

0.006 mg/L

0.0003 mg/L

0.0005 mg/L

95.70

90.91

0.002 mg/L

 

 

 

 

 

 

 

 

 

Mercury at pH 8.5

0.002 mg/L

.006 mg/L ± 10%

0.006 mg/L

0.0008 mg/L

0.0015 mg/L

86.22

75.93

0.002 mg/L

 

 

 

 

 

 

 

 

 

Atrazine

0.003 mg/L

0.009 mg/L + 10%

0.009 mg/L

<0.002 mg/L

0.002 mg/L

76.99

75.31

0.003 mg/L

 

 

 

 

 

 

 

 

 

Benzene

0.005 mg/L

0.015 mg/L ± 10%

0.014 mg/L

0.0006 mg/L

0.0011 mg/L

95.71

92.14

0.005 mg/L

 

 

 

 

 

 

 

 

 

Carbofuran

0.04 mg/L

0.08 mg/L ± 10%

0.081 mg/L

<0.001 mg/L

<0.001 mg/L

98.74

98.46

0.04 mg/L

 

 

 

 

 

 

 

 

 

p-Dichlorobenzene

0.075 mg/L

.225 mg/L ± 10%

0.208 mg/L

<0.0005 mg/L

<0.0005 mg/L

99.76

99.74

0.075 mg/L

 

 

 

 

 

 

 

 

 

 

0.0002

 

 

 

 

 

 

 

Lindane

mg/L

0.002 mg/L ± 10%

0.002 mg/L

0.000 mg/L

<0.0001 mg/L

98.72

96.50

0.0002 mg/L

 

 

 

 

 

 

 

 

 

Toxaphene

0.003 mg/L

0.015 ± 10%

0.015 mg/L

<0.001 mg/L

<0.001 mg/L

92.97

91.67

0.003 mg/L

 

 

 

 

 

 

 

 

 

*Tested using a flow rate of 0.78 gpm; pressure of 60 psig; pH of 7.5 + 0.5; temp. of 68° + 5°F (20° + 3°C)

**Measurement in Particules/ml. Particules used were 0.5 - 1 microns

***NTU - Nephelometric Turbidity Units

SPECIFICATIONS

Rated Flow:

.78 gpm (2.9 L/min)

Min. Op.Temp:

33° F (.6° C)

Max. Op.Temp:

100° F (38° C)

Min. Op. Press:

35 psi (241 kPA)

Max. Op. Press:

120 psi (827 kPA)

General Use Conditions

Read this Performance Data Sheet and compare the capabilities of this unit with your actual water treatment needs.

DO NOT use this product where water is microbiologically unsafe or of unknown quality without adequate disinfection before or after the system. System certified for cyst reduction may be used on disinfected water that may contain filterable cysts.

USE ONLY WITH COLD WATER SUPPLY. CHECK FOR COMPLIANCE WITH THE STATE AND LOCAL LAWS AND REGULATIONS.

System tested and certified by NSF International against NSF/ANSI Std 42 for the reduction of Chlorine Taste and Odor, Particulate Class I and against NSF/ ANSI 53 for the reduction of Cysts, Turbidity,Asbestos, Mercury, Lead, Benzene, p-Diclorobenzene, Carbofuran

The AquaClean™ retractable water filtration system uses an AFF3 replacement cartridge. Timely replacement of filter cartridge is essential for performance satisfaction from this filtration system. Please refer to the applicable section of your Use and Care Guide for general operation, maintenance requirements and troubleshooting.

This system has been tested according to ANSI/NSF 42 and 53 for reduction of the substances listed above. The concentration of the indicated substances in water entering the system was reduced to a concentration less than or equal to the permissible limit for water leaving the system, as specified in ANSI/NSF 42 and 53.