Planning the Installation
Selecting the Location
•Carefully check the location where the oven is to be installed. The oven should be placed for convenient access, but away from drafts that may be caused by doors, windows, and heating, ventilation and air conditioning outlets.
•Make certain that electrical power can be provided in the selected location. Be certain that proper clearance is provided for the oven door when it is in the open position.
Cabinet Cut-Out
•Plan the installation so that all minimum clearances are met or exceeded. Cutout dimensions shown provide minimum clearances, unless otherwise noted.
•The specified minimum cabinet depth and width must be provided. The cabinet depth and width must completely enclose the recessed portion of the oven.
•Cabinet cutout dimensions must be used as indi- cated.
| “C” |
|
|
| Recommended |
|
| Electrical |
|
| Location |
1“ (25mm) Min. |
|
|
Clear to Top of | Single Wall | |
Door for Heat | ||
Exhaust | Oven Cutout | |
| ||
| “A” |
|
| “B” |
|
| 3/4” (19mm) | Alternate |
| Electrical | |
| Support Platform | Location |
1 ¾“ (45mm) Min. |
|
|
Clear to Top of |
|
|
Door for Heat |
|
|
Exhaust |
|
|
|
| 31 1/4” (794mm) |
|
| Recommended |
|
| (May be Altered) |
| 4“ Typical Toe Kick (Shown) |
|
Model | A | B | C | D | |
Number | |||||
|
|
|
| ||
EO127 |
|
|
|
| |
PO127 |
| 25 1/2” | 27” | 56 1/2” | |
MOV127 |
| (648mm) | (686mm) | (1435mm) | |
MOH127 | 27 7/16” |
|
|
| |
EO130 | (697mm) |
|
|
| |
PO130 |
| 28 1/2” | 30” | 62 1/2” | |
MOV130 |
| (724mm) | (762mm) | (1588mm) | |
MOV130 |
|
|
|
| |
EO227 |
|
|
|
| |
PO227 |
| 25 1/2” | 27” |
| |
MOV227 |
| (648mm) | (686mm) |
| |
MOH227 | 50 9/16” |
|
| NA | |
EO230 | (1284mm) |
|
| ||
|
|
| |||
PO230 |
| 28 1/2” | 30” |
| |
MOV230 |
| (724mm) | (762mm) |
| |
MOH230 |
|
|
|
|
| “C” | |
| Recommended | |
| Electrical | |
| Location | |
1“ (25mm) |
| |
Clear to Top |
| |
of Drawer for |
| |
Heat Exhaust |
| |
| “B” | |
| “A” | |
| Double Wall | |
| Oven Cutout | |
| 3/4” (19mm) | |
| Support Platform | |
1 ¾“ (45mm) | 9 5/8” (244mm) | |
Recommended | ||
Clear to Top | ||
(May be altered) | ||
of Drawer for | ||
4“ Typical Toe Kick (Shown) | ||
Heat Exhaust | ||
|