Installation Instructions

Electrical Service Installation

warning

Wire the oven only in compliance with local ordinanc- es.

If the electrical service provided does not meet the product specifications, do not proceed with the instal- lation. Call a licensed electrician to install the required wiring.

To prevent an electric shock or fire hazard, turn off power to the circuit at the circuit breaker or fuse box prior to connecting the wiring to the oven.

Improper connection of the electrical wiring can cause an electric shock hazard and damage the appliance. Dacor is not responsible for damages resulting from improper installation.

Connect the ground terminal (or lead) on the appliance to a grounded, metallic, permanent wiring system or grounding conductor.

Do not use an extension cord with this appliance. Such use may result in fire, electric shock or other per- sonal injury.

Do not install a fuse in the neutral or ground circuit. A fuse in the neutral or ground circuit may result in an electric shock hazard.

The appliance must be connected to the power supply with copper wire only. The use of aluminum wire may result in unsatisfactory connections.

Flexible armored or non-metallic, sheathed copper cable (with grounding wire) should be used to connect the appliance to the junction box. An UL-listed connec- tor must be used to directly connect the cable to the junction box.

IMPORTANT

Make sure that the conduit is long enough to allow the oven to be pulled out for service without disconnecting it from power.

1.Before proceeding, turn off power to the circuit to which the oven will be connected at the circuit breaker or fuse box.

2.Position the oven directly in front of the cabinet cutout.

3.Feed the appliance conduit into the electrical junction box and attach it using a UL approved strain relief.

4.Depending upon local codes, utilize one of three meth- ods to connect the appliance to the electrical power:

Connect to a four (4) wire electrical system

Connect to a three (3) wire electrical system, where local codes permit

Connect to a three (3) wire electrical system with external ground, according to local codes.

Connecting to a Four (4) Wire Electrical System

1.Separate the wires coming out of the appliance conduit.

2.Connect the white wire from the appliance conduit to the white (neutral) supply wire in the junction box.

3.Connect the black wire from the appliance conduit to the black (L1) supply wire in the junction box.

4.Connect the red wire from the appliance conduit to the red (L2) supply wire in the junction box.

5.Connect the green wire from the appliance conduit to the green (ground) wire in the junction box.

Cable from circuit breaker

panel or fuse box

Junction box

RED

WHITE

RED

WHITE

 

GREEN

BLACK

GREEN

BLACK

 

Wire nut

(4 places)

Conduit to wall oven

Four (4) Wire Junction Box Connection

10