Operating Your Outdoor Grill

LP Tank Connection

Instructions for LP tank connection and use for outdoor grills equipped for use with a portable LP tank.

warning

Dacor outdoor grills are factory equipped for use with either LP or natural gas. DO NOT ATTEMPT FIELD CONVERSIONS FROM LP TO NATURAL GAS OR FROM NATURAL GAS TO LP.

Use only a U.S. DOT or CSA approved LP gas supply tank. The LP tank must include a collar to protect the tank valve. A LP tank must be provided with a shut-off valve terminating in a liquid petroleum (LP) gas supply cylinder valve outlet specified, as applicable, for connection type 1. The cylinder supply system must be arranged for vapor withdrawal and provided with a listed overfilling prevention device.

Never use a dented or rusty LP tank. If there is any question as to the soundness of the tank, have it checked by your LP supplier. Never use a tank with a damaged or defective shut-off valve.

Use only the type 1 connector, hose and regulator assembly supplied with the outdoor grill, or a Dacor approved replacement.

When the LP tank is enclosed, it must be ventilated by openings on the sides, back and floor of the enclosure. Each opening must have a total area of no less than 10 square inches. Keep the ventilation openings for the LP tank free and clear from debris.

Check the gas supply line for damage before each use. Check for leaks after every tank change. NEVER check for leaks using a match or open flame.

Do not use a tool to connect a LP tank. Damage resulting in an explosion hazard may occur.

Always handle LP tanks with care. Do not drop or bump against sharp objects.

When disconnecting and/or transporting a LP tank, always close the shut-off valve and cover the connector. Always keep a LP tank in the upright position. Keep it away from any sources of high heat.

Never fill and LP tank beyond 80 percent full (by weight).

Unused or extra LP tanks must be stored outdoors in a well-ventilated area out of the direct sunlight and/or sources of high heat, flames or sparks, out of reach of children. Do not store additional LP tanks in the enclosure under the unit. Cover the hose connection on the tank with a cover.

Always close the shut-off valve on the LP tank when the appliance is not in use.

An LP cylinder not connected for use shall not be stored in the vicinity of this or any other appliance.

If the outdoor grill is stored indoors, the LP tank must be disconnected and removed from the appliance.

If the above instructions are not followed exactly, a fire or explosion causing death or serious injury may occur.

Dacor outdoor grills are approved for a maximum LP tank capacity of 20 pounds (5 gallons). The tank must be con- structed and marked in accordance with the specifications for LP-gas tanks of the U.S. Department of Transportation (DOT) or the National Standard of Canada, CAN/CSA- B339, tank, Spheres and Tubes of the Transportation of Dangerous Goods.

To Connect the LP Tank:

1. Check the gas connector from the outdoor grill and

the LP tank connector. Make sure no dirt has accumu-

5.After hose connector installation, open (turn on) the shut-off valve and check for leaks. Use a spray bottle to spray a soapy solution onto all the gas connections.

If the solution bubbles, there is a leak. Close the shut- off valve and have the gas line repaired by a qualified service technician.

6.Close the gas shut-off valve.

Gas shut-off valve

Flexible LP gas line

from outdoor grill

 

 

lated inside. If there is debris inside, brush it out with

 

a soft bristled brush or jet of air.

2.

Put the LP tank in position under the appliance.

3.

Make sure the gas shut-off valve on top of the LP tank

 

is completely closed.

4.

Insert the hose connector into the valve outlet.

 

Tighten the plastic collar firmly into place. Hand

 

tighten only.

LP tank storage shelf

on optional cart

Factory equipped regulator

LP tank

5 gallon Max.

8

Page 37
Image 37
Dacor OBS36, OBSB162, OBS52, OB52, OB36 specifications Operating Your Outdoor Grill, LP Tank Connection, To Connect the LP Tank