Operating Your Raised Vent

Important Safety Instructions

Operation warning

Before operating the raised vent, verify that pot handles or other objects will not interfere with the raising and lowering of the vent intake. To prevent spillage and damage to the vent system, turn cookware handles to the side so that they will not be hit when the vent moves to the “up” position.

Clean liquid spills immediately. If liquid enters the vent intake, then turn off the blower, disconnect the power supply and carefully wipe up all liquid. See the Care and Cleaning section of this manual.

Never operate the vent without the filters in place.

Do not operate the blower if a flame or flare-up develops. In the event of a flame, immediately turn off the blower. Smother the flame or use an appropriate class dry chemical or foam-type fire extinguisher.

Parts the of Raised Vent - Shown Raised warning

Do not set or rest any objects, including cookware, on top of the vent top cap. Do not interfere with the movement of the vent intake in any way.

If the vent intake becomes jammed while being raised or lowered, immediately press the Up/ Down switch once to stop the intake motion, then disconnect the power supply. Remove the obstruction, then restore power and press the Up/ Down switch to continue raising or lowering the intake.

Clean this appliance only as instructed in this manual. Use only the cleaners specified.

Never leave a cooktop or range unattended during use.

Operating Your Raised Vent

Operation

UP/DOWN OFF warning

If the vent intake becomes jammed while being raised or lowered, immediately press the UP/DOWN key once to stop the intake motion, then disconnect the power cord. Remove the obstruction, reconnect the power plug and press the UP/DOWN key to continue raising or lowering the intake.

Manual background important

The direction of travel of the vent intake cannot be reversed while it is moving. The intake must complete a full up or down cycle before changing directions.

To operate the RV raised vent system when the vent intake is in its lowered position, press and release the UP/DOWN key on the control panel. The intake will take approximately ten seconds to reach its uppermost posi- tion, where it will stop.

The blower will turn on automatically and run on the high speed setting. Adjust the blower speed by pressing and releasing either the MEDIUM or LOW keys. The fan speed may be changed whenever desired, as long as the vent intake is in the fully raised position. The blower will not operate if the intake is in any other position.

Turn off the blower in one of two ways: Press and release the OFF key or lower the vent by pressing and releasing the UP/DOWN key.

Control Panel

Top Cap

Intake

Grill

Parts the of Raised Vent - Shown Raised

Appearance varies with model number

UP/DOWN OFF

LOW MEDIUM HIGH