Care and Cleaning
Cleaning the Intake Panel
The intake panels accumulate grease over time and should be cleaned whenever the filters are washed.
•After removing the grill and filters, wipe all external and internal aluminum surfaces with a sponge or cloth moistened with a mild detergent. Rinse off with water. Remove all moisture by wiping with a soft, dry polish- ing cloth. Always wipe in the direction of the grain. Do not use any abrasive substances on the intake panels, as this may permanently mar the finish.
•Dry and reinstall all components prior to operating the vent system.
Cleaning the Top Cap
Clean the top cap only when the intake vent is in the low- ered position.
The top cap and end caps may have painted finishes (depending on the model) that will scratch or stain if cleaned with abrasive materials or harsh chemicals.
•Gently wipe them with a sponge or soft cloth moist- ened in a mild detergent solution whenever they becomes soiled. Avoid introduction of moisture into the electronic keypad area.
Cleaning the Electronic Keypad
Do not use any abrasive materials to clean the keypad.
•The keypad and surrounding the plastic bezel should be gently wiped with a lightly dampened sponge or cloth. Any material that becomes lodged between the buttons and the surrounding bezel may be removed by carefully dabbing with a cotton swab or the edge of a cloth. Use the above method to prevent the buttons from sticking.
•After cleaning, immediately dry the keypad area with a soft cloth.
Before You Call for Service
Problem Solution Guide
problem
may be caused by
what to DO
Nothing works. | Raised vent not connected to elec- | Make sure power plug is connected to electri- |
| trical power. | cal outlet. |
|
|
|
| Power to vent’s electrical outlet is | Turn on power at circuit breaker or fuse box. |
| off. | Check for tripped breaker or blown fuse. |
|
|
|
| Power outage. | Contact power company. |
|
|
|
| Keypad is deactivated. | Reactivate control panel: press high and low |
|
| keys at the same time. Hold down for one |
|
| second. |
|
|
|
Vent intake raises or lowers | An obstruction is interfering with | Immediately press Up/Down key, then discon- |
partially then stops. | the vent intake movement. | nect the power plug. Remove the obstruction. |
|
| Reconnect the vent power plug and press Up/ |
|
| Down key to raise or lower intake. |
|
|
|
Gas flame is being pulled by | Short duct run or high output of | Reduce blower speed to a lower setting. |
draw of vent. | system make ventilating force very |
|
| strong. |
|
|
|
|
Clean filter symbol is lit. | Blower has operated for over 40 | Inspect and clean filters. See Care and Clean- |
| hours. | ing section. |
|
|
|
6