INSTRUCTION OF INSTALLATION
Below is an overview for the connection of the Indoor unit to the Outdoor unit.
OVERVIEW
This appliance must be installed according to national power supply acquirement.
10cm (3.95in)
from ceiling 30cm (11.8in) from side wall
10cm (3.95in) from
side wall
At least 30cm (11.8in) from unit
AC Outlet
and Plug
| Wall |
|
Wall | Drain |
|
Bracket | Hose | Wall Cap |
|
|
Oxygen tube
Pipes
(Not Supplied)
AC
Connection
(Not Supplied)
Wrap with
Tape
10 | cm |
|
3.9 inches
NOTES:
• After installation it must be |
possible for the user to dis - |
connect the power supply |
plug. |
• If the AC outlet is a 3- |
pronged type or other, have |
an electrician install a new |
outlet. |
• Contanct service man when |
Plug into 220V~240V
AC Outlet
23.6 | 60 | |
cm | ||
inches | ||
|
60 | 23.6 | |
cm | ||
inches | ||
|
Maximum Height | 7M (21Ft) |
Maximum Length | 15M (49Ft) |
Any tube length between 7 and 15 meters must
be precharged with freon using the following calulation:
(Length – 5) x 30 grams
Adding additonal tubing will decrease efficiency
27.6 inches
70 | cm |
Copper |
|
|
| Drain |
|
|
| ||
|
|
| ||
|
|
| ||
Tubing |
|
|
| Hose |
|
|
| ||
|
|
|
|
Ground Wire
(Not Supplied)
replace the power cord set. |
• The specification of AC con - |
nection is 2.0mm2 x 3C x 6m. |
| 5/8" side piping |
| 5/8" side piping |
Connecting | Oxygen tube | Connecting | Oxygen tube |
cable | 3/8" side piping | cable | 3/8" side piping |
| Drain Hose |
| Drain Hose |
Cooling Only | Heating & Cooling |
*