Daewoo KOC-1B0K0S service manual High voltage circuit wiring

Models: KOC-1B0K0S

1 38
Download 38 pages 16.86 Kb
Page 12
Image 12

6. To remove high voltage capacitor.

(1) Remove a screw which secure the groun- ding ring terminal of the H.V.diode and the capacitor holder.

(2) Remove the H.V. diode from the capacitor holder.

(3) Reverse the above steps for reassembly.

l High voltage circuit wiring

7. To remove magnetron.

(1) Remove a screw which secure the magnetron.

(2) Remove the magnetron.

(3) Reverse the above steps for reassembly.

CAUTION : Never install the magnetron without the metallic gasket plate which is packed with each magnetron to prevent microwave leakage. Whenever repair work is carried out on magnetron, check the microwave leakage. It shall not exceed 4mW/cm2 for a fully assembled oven with door normally closed.

Metallic

Magnetron antenna

 

gasket

 

plate

 

Cooling fin

Filament terminal

11

Page 12
Image 12
Daewoo KOC-1B0K0S service manual High voltage circuit wiring