8.To remove fan motor assembly

CAUTION : Never install the magnetron without the metallic gasket plate which is packed with each magnetron to prevent microwave leakage. Whenever repair work is carried out on magnetron, check the microwave leakage. It shall not exceed 4mW/cm2 for a fully assembled oven with door normally closed.

 

Magnetron

 

 

Antenna

 

Metallic

Wave Guide

Magnetron Antenna

Gasket

 

 

Plate

 

 

Cooling Fin

Metallic Gasket Plate

Filament

Magnetron Terminal

8.To remove fan motor assembly

(1)Remove two screws ¤ which secure the back cover ¤Ł from the cavity outer.

(2)Remove two screws ¤Øwhich secure the fan motor ¤Œ from the back cover ¤Ł .

(3)Pull out the fan ¤º from the fan motor ¤Œ .

(4)Reverse the above steps for reassembly.

1

3

5

1

2

4

9.To remove transformer

(1)Remove the two screws ¤ holding the H.V. trans- former ¤Ł .

(2)Remove the transformer ¤Ł.

(3)Reverse the above steps for reassembly.